MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/smll.201100651

Медицинская библиотека · Small (Weinheim an der Bergstrasse, Germany) · 2011

Antioxidant deactivation on graphenic nanocarbon surfaces.

Liu Xinyuan, Sen Sujat, Liu Jingyu, Kulaots Indrek, Geohegan David, Kane Agnes, Puretzky Alex A, Rouleau Christopher M, More Karren L, Palmore G Tayhas R, Hurt Robert H

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

This article reports a direct chemical pathway for antioxidant deactivation on the surfaces of carbon nanomaterials. In the absence of cells, carbon nanotubes are shown to deplete the key physiological antioxidant glutathione (GSH) in a reaction involving dissolved dioxygen that yields the oxidized dimer, GSSG, as the primary product. In both chemical and electrochemical experiments, oxygen is only consumed at a significant steady-state rate in the presence of both nanotubes and GSH. GSH deactivation occurs for single- and multi-walled nanotubes, graphene oxide, nanohorns, and carbon black at varying rates that are characteristic of the material. The GSH depletion rates can be partially unified by surface area normalization, are accelerated by nitrogen doping, and suppressed by defect annealing or addition of proteins or surfactants. It is proposed that dioxygen reacts with active sites on graphenic carbon surfaces to produce surface-bound oxygen intermediates that react heterogeneously with glutathione to restore the carbon surface and complete a catalytic cycle. The direct catalytic reaction between nanomaterial surfaces and antioxidants may contribute to oxidative stress pathways in nanotoxicity, and the dependence on surface area and structural defects suggest strategies for safe material design.

Для цитирования: Liu Xinyuan, Sen Sujat, Liu Jingyu, Kulaots Indrek, Geohegan David, Kane Agnes, Puretzky Alex A, Rouleau Christopher M, More Karren L, Palmore G Tayhas R, Hurt Robert H. Antioxidant deactivation on graphenic nanocarbon surfaces.. Small (Weinheim an der Bergstrasse, Germany). 2011. DOI: 10.1002/smll.201100651.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.