MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00002030-199409000-00009

Медицинская библиотека · AIDS (London, England) · 1994

Anti-A60 immunoglobulin G in the serodiagnosis of tuberculosis in HIV-seropositive and seronegative patients.

Pouthier F, Perriëns J H, Mukadi Y, Kayembe T, St Louis M E, Brown C, Prignot J

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

A60 is a high molecular weight mycobacterial antigen complex. The detection of immunoglobulin (Ig) G antibodies to A60 has been advocated as a reasonably sensitive and specific test for active tuberculosis (TB). We aimed to compare the sensitivity of this test among HIV-seropositive and HIV-seronegative patients with pulmonary TB.

METHODS

The presence and concentration of anti-A60 IgG antibodies was assessed by enzyme-linked immunosorbent assay in 208 HIV-seropositive and 91 HIV-seronegative Zaïrian patients with smear-positive pulmonary TB. The relationship between anti-A60 IgG levels and HIV serostatus, CD4+ lymphocyte counts, presence of clinical AIDS, and tuberculin skin test results was verified.

RESULTS

Only 36.5% of the HIV-seropositive, compared with 69.2% of the HIV-seronegative patients had a positive anti-A60 IgG test (P < 0.00001). Among HIV-seropositive patients, anti-A60 IgG levels did not differ according to CD4+ lymphocyte counts, presence of clinical AIDS, or tuberculin skin test results.

CONCLUSIONS

Among patients with pulmonary TB, the sensitivity of testing for anti-A60 IgG was much lower among HIV-seropositive than among HIV-seronegative patients, even from the early stages of HIV-related immunodeficiency. This limits the utility of anti-A60 IgG-antibody testing in the diagnosis of TB among HIV-infected patients.

Для цитирования: Pouthier F, Perriëns J H, Mukadi Y, Kayembe T, St Louis M E, Brown C, Prignot J. Anti-A60 immunoglobulin G in the serodiagnosis of tuberculosis in HIV-seropositive and seronegative patients.. AIDS (London, England). 1994. DOI: 10.1097/00002030-199409000-00009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.