Simple assay system for detecting human T cell leukemia virus type I-binding cells and its application in titrating binding inhibitory antibodies.

Akari H, Kannagi M, Shinjo T, Harada S

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

A simple and rapid assay system for the detection of human T cell leukemia virus type I (HTLV-I) binding cells was developed to assess the virus specific receptor and titrate the antibodies to block the virus binding.

EXPERIMENTAL

DESIGN

Cells (5 x 10(5)) were incubated with 100 microliters of the concentrated HTLV-I at 37 degrees C for 1 hour. After washing, the cells were reacted with anti-HTLV-I envelope monoclonal antibody (rat) for 30 minutes on ice and then stained with fluorescein-isothiocyanate-conjugated anti-rat immunoglobulin. The stained samples were analyzed on FACScan. Antibody-titration of the virus-binding inhibition was carried out by pretreatment of the virus with serially diluted sera.

RESULTS

The specificity of the virus-binding was shown by dose-response relationship, kinetics of the binding, and temperature dependency. HTLV-I was absorbed onto a wide range of human cell lines and peripheral blood lymphocytes at various levels. Antibodies to inhibit the virus-binding were also quantitatively detected in sera from HTLV-I infected individuals, including asymptomatic carriers and patients with adult T cell leukemia or HTLV-I-associated myelopathy, but not from healthy seronegative controls.

CONCLUSIONS

This assay system would be useful in screening the virus-specific receptor and the neutralizing antibodies to HTLV-I. Thus, the assay could be applied to further studies on HTLV-I-related diseases.

Для цитирования: Akari H, Kannagi M, Shinjo T, Harada S. Simple assay system for detecting human T cell leukemia virus type I-binding cells and its application in titrating binding inhibitory antibodies.. Laboratory investigation; a journal of technical methods and pathology. 1993.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.