Bottio T, Gerosa G, Basso C, Thiene G, Casarotto D C
Аннотация
BACKGROUND AND AIMS: The longevity of the mechanical heart valve prosthesis is an advantage when compared with its biological counterpart, although the former carries a risk of thrombosis depending on valve design, materials and host-related interface; therefore, a patient with a mechanical valve prosthesis, particularly in mitral position, is at risk for systemic thromboembolism even when properly anticoagulated.
PATIENTS AND METHODS: We report a case of a 60-year-old woman who underwent a mitral valve replacement with a St. Jude Medical (SJM) standard bileaflet mechanical heart valve.
RESULTS: On the twelfth post-operative day a primary thrombosis with blockage of the anterior valve leaflet occurred.
CONCLUSIONS: Aware of the risk of recurrent thromboembolism in this special clinical framework and possible cerebral bleeding in case of thrombolysis, we replaced the prosthesis with a new biologic porcine valve, the SJM Biocor.
PATIENTS AND METHODS: We report a case of a 60-year-old woman who underwent a mitral valve replacement with a St. Jude Medical (SJM) standard bileaflet mechanical heart valve.
RESULTS: On the twelfth post-operative day a primary thrombosis with blockage of the anterior valve leaflet occurred.
CONCLUSIONS: Aware of the risk of recurrent thromboembolism in this special clinical framework and possible cerebral bleeding in case of thrombolysis, we replaced the prosthesis with a new biologic porcine valve, the SJM Biocor.