MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.cir.85.4.1447

Медицинская библиотека · Circulation · 1992

Reduced left ventricular compliance in human mitral stenosis. Role of reversible internal constraint.

Liu C P, Ting C T, Yang T M, Chen J W, Chang M S, Maughan W L, Lawrence W, Kass D A

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The mechanisms of depressed left ventricular (LV) pump performance in human mitral stenosis (MS) remain poorly understood, because reduced filling alone affects many hemodynamic measurements. Therefore, pressure-volume relations were examined in nine subjects with MS and compared with eight age-matched normal controls.

METHODS AND

RESULTS

Data were obtained by conductance catheter/micromanometer technique with transient inferior vena cava occlusion used to alter load and generate pressure-volume relations. In a subset of patients (n = 5), data were obtained both acutely and at 3 months (n = 4) after balloon valvuloplasty. MS patients had reduced cardiac output (3.3 +/- 0.9 versus 5.6 +/- 1.7 l/min) and end-diastolic volume (68.0 +/- 6.9 versus 115 +/- 31 ml) versus controls (p less than 0.001), with a mean transvalvular gradient of 14 +/- 6 mm Hg and estimated valve area of 0.6 +/- 0.2 cm2. Systolic function as assessed by the end-systolic pressure-volume relation was virtually the same in MS and control subjects. In contrast, end-diastolic pressure-volume relations in MS were consistently shifted leftward and had an increased slope (lower compliance) at matched pressure ranges (6.5 +/- 3.0 versus 2.2 +/- 0.53 ml/mm Hg at a mean diastolic pressure of 8 mm Hg, p less than 0.001). This change was not a result of reduced LV filling or probably of increased right heart loading. Valvuloplasty acutely returned chamber compliance to near normal, a change that was sustained at 3-month follow-up. Systolic function was little altered at this time.

CONCLUSIONS

These data indicate an impairment of diastolic function in human MS that can be acutely reversed by balloon valvuloplasty. Lowered LV compliance probably results from a functional restriction caused by ventricular attachment to a thickened and immobile valve apparatus.

Для цитирования: Liu C P, Ting C T, Yang T M, Chen J W, Chang M S, Maughan W L, Lawrence W, Kass D A. Reduced left ventricular compliance in human mitral stenosis. Role of reversible internal constraint.. Circulation. 1992. DOI: 10.1161/01.cir.85.4.1447.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.