MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejca.2018.03.006

Медицинская библиотека · European journal of cancer (Oxford, England : 1990) · 2018

Detection of immune-related adverse events by medical imaging in patients treated with anti-programmed cell death 1.

Mekki Ahmed, Dercle Laurent, Lichtenstein Philip, Marabelle Aurélien, Michot Jean-Marie, Lambotte Olivier, Le Pavec Jérôme, De Martin Eleonora, Balleyguier Corinne, Champiat Stéphane, Ammari Samy

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Programmed death receptor-1 blocking antibodies (anti-PD1) are a new standard of care in many cancer types. Patients benefit from improved survival but have the risk of immune-related adverse events (irAE). We evaluated if medical imaging procedures, used for anti-tumour response assessment, can detect irAEs.

MATERIALS AND

METHODS

All consecutive patients treated with anti-PD1 and with a medical imaging acquisition performed within 2 weeks with irAEs ≥2 were retrospectively included. Data were gathered from June 2014 to February 2017, and a central review was performed. The primary and secondary end-points were i) to evaluate the overall detection rate of irAEs by medical imaging and ii) to provide a comprehensive radiological description of irAEs.

RESULTS

Fifty-three patients (31 women, 22 men; average age: 61 years) were included. The primary tumour was melanoma (n = 32), lung cancer (n = 18) and other (n = 3). Patients were treated with nivolumab (n = 27) or pembrolizumab (n = 26). Of 74 medical imaging procedures analysed (ratio = 1.4 medical imaging per patient), 55 irAE were detected. The detection rate was overall: 74% (95 confidence interval: 63-84%), positron emission tomography with 18F-fludeoxyglucose integrated with computed tomography (18F-FDG PET/CT): 83% (n = 10/12), magnetic resonance imaging: 83% (n = 5/6), computed tomography scan: 79% (n = 19/24), ultrasonography: 70% (n = 19/27), standard X-rays: 40% (n = 2/5), lung/mediastinum: 100% (n = 7/7), enterocolitis: 100% (n = 8/8), hypophysitis: 100% (n = 3/3), thyroiditis: 75% (n = 15/20), hepatitis: 67% (n = 2/3), arthralgia or arthritis: 40% (n = 2/5) and pancreas: 28% (n = 2/7).

CONCLUSION

Medical imaging detected 74% of irAE in patients treated with anti-PD1. Beyond response assessment, medical imaging can detect irAE and guide towards specific management. We described the most frequent sites and patterns of imaging findings.

Для цитирования: Mekki Ahmed, Dercle Laurent, Lichtenstein Philip, Marabelle Aurélien, Michot Jean-Marie, Lambotte Olivier, Le Pavec Jérôme, De Martin Eleonora, Balleyguier Corinne, Champiat Stéphane, Ammari Samy. Detection of immune-related adverse events by medical imaging in patients treated with anti-programmed cell death 1.. European journal of cancer (Oxford, England : 1990). 2018. DOI: 10.1016/j.ejca.2018.03.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.