DOI 10.1016/j.taap.2013.07.003

Медицинская библиотека · Toxicology and applied pharmacology · 2013

An epidermal equivalent assay for identification and ranking potency of contact sensitizers.

Gibbs Susan, Corsini Emanuela, Spiekstra Sander W, Galbiati Valentina, Fuchs Horst W, Degeorge George, Troese Matthew, Hayden Patrick, Deng Wei, Roggen Erwin

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The purpose of this study was to explore the possibility of combining the epidermal equivalent (EE) potency assay with the assay which assesses release of interleukin-18 (IL-18) to provide a single test for identification and classification of skin sensitizing chemicals, including chemicals of low water solubility or stability. A protocol was developed using different 3D-epidermal models including in house VUMC model, epiCS® (previously EST1000™), MatTek EpiDerm™ and SkinEthic™ RHE and also the impact of different vehicles (acetone:olive oil 4:1, 1% DMSO, ethanol, water) was investigated. Following topical exposure for 24h to 17 contact allergens and 13 non-sensitizers a robust increase in IL-18 release was observed only after exposure to contact allergens. A putative prediction model is proposed from data obtained from two laboratories yielding 95% accuracy. Correlating the in vitro EE sensitizer potency data, which assesses the chemical concentration which results in 50% cytotoxicity (EE-EC50) with human and animal data showed a superior correlation with human DSA05 (μg/cm(2)) data (Spearman r=0.8500; P value (two-tailed)=0.0061) compared to LLNA data (Spearman r=0.5968; P value (two-tailed)=0.0542). DSA05=induction dose per skin area that produces a positive response in 5% of the tested population Also a good correlation was observed for release of IL-18 (SI-2) into culture supernatants with human DSA05 data (Spearman r=0.8333; P value (two-tailed)=0.0154). This easily transferable human in vitro assay appears to be very promising, but additional testing of a larger chemical set with the different EE models is required to fully evaluate the utility of this assay and to establish a definitive prediction model.

Для цитирования: Gibbs Susan, Corsini Emanuela, Spiekstra Sander W, Galbiati Valentina, Fuchs Horst W, Degeorge George, Troese Matthew, Hayden Patrick, Deng Wei, Roggen Erwin. An epidermal equivalent assay for identification and ranking potency of contact sensitizers.. Toxicology and applied pharmacology. 2013. DOI: 10.1016/j.taap.2013.07.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.