MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11701-026-03736-4

Медицинская библиотека · Journal of robotic surgery · 2026

Feasibility of a novel multi-device robotic system for multiple neurointerventional procedures: pre-clinical validation in porcine models.

Zhang Yongxin, Ma Hongyu, Li Jiayan, Guo Fei, Guo Jian, Sun Jun, Liu Jianmin, Guo Shuxiang, Yang Pengfei

СтатьяПеревод пока не подготовлен

Аннотация

While the application of a robotic system in neurointerventional procedures has gained notable attention, the current robotic assistance is unsatisfactory. Therefore, we developed a novel robotic system, which was capable of simultaneous coaxial control of three catheters and one guidewire, coupled with rapid-exchange functionality. To evaluate the feasibility of the multi-device robotic system for diagnostic angiography, carotid artery stenting (CAS), vertebral artery (VA) stenting, flow diverter (FD) deployment and aneurysm coiling through preclinical study. The robotic system was tested for feasibility to complete all procedural steps of 5 neurovascular interventions navigating or deploying a variety of common neurovascular devices including the guidewires, catheters, micro-guidewires, microcatheters, coils, the FD, the cerebral protection device and different types of stents. The experimental lateral wall aneurysms were created in 3 live and anesthetized pigs by end-to-side anastomosis using an autologous venous pouch. A total of five surgically created aneurysms were allocated to coiling (n = 2), FD implantation (n = 2) and coiling + FD (n = 1). One VA and one CA were utilized for stenting. All planned procedures were performed successfully with no relevant technical complications or vascular damage. Notably, almost all procedural steps, from different navigation of catheters to device deployment, were completed robotically, with manual intervention limited to radiation-free device exchanges and loading. Robot-assisted operation does not increase the complexity of procedures. This pilot study demonstrates that the multi-device robotic system is feasible for cerebral angiography, navigation of the guiding catheter, aneurysm coiling, FD deployment, VA stenting and CAS.

Для цитирования: Zhang Yongxin, Ma Hongyu, Li Jiayan, Guo Fei, Guo Jian, Sun Jun, Liu Jianmin, Guo Shuxiang, Yang Pengfei. Feasibility of a novel multi-device robotic system for multiple neurointerventional procedures: pre-clinical validation in porcine models.. Journal of robotic surgery. 2026. DOI: 10.1007/s11701-026-03736-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.