MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2013.05.001

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2013

Three-dimensional transesophageal echocardiographic evaluation of coronary involvement in patients with acute type A aortic dissection.

Sasaki Shunsuke, Watanabe Hiroyuki, Shibayama Kentaro, Mahara Keitaro, Tabata Minoru, Fukui Toshihiro, Tobaru Tetsuya, Takanashi Shuichiro, Sumiyoshi Tetsuya, Tomoike Hitonobu

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Acute Stanford type A aortic dissection (AAD) with coronary involvement is associated with high mortality. However, coronary involvement is not always successfully visualized by computed tomography and two-dimensional (2D) transesophageal echocardiography (TEE). The aim of this study was to test the hypothesis that three-dimensional (3D) TEE can detect coronary involvement in patients with AAD.

METHODS

Fifty-one consecutive patients with AAD who underwent intraoperative TEE using an iE33 system during emergency surgery were enrolled. Using computed tomographic images, conventional 2D transesophageal echocardiographic images, and a 3D transesophageal echocardiographic data set, the status of coronary ostia was evaluated and classified into four types-branching from true lumen, branching from false lumen, dissection, and unclear-and these results were compared with operative findings.

RESULTS

In six patients, coronary involvement was diagnosed operatively by surgeons. They comprised dissection at three left coronary ostia and branching from false lumen at three right coronary ostia. All six cases were successfully detected by both 2D TEE and 3D TEE before instituting cardiopulmonary bypass. However, in 45 patients (90 ostia) confirmed operatively as having no coronary involvement, 69 ostia by computed tomography (36 in the left and 33 in the right coronary artery) and 16 ostia by 2D TEE (four in the left and 12 in the right coronary artery) were evaluated as unclear coronary involvement. On the other hand, 3D TEE clearly depicted no coronary involvement in all but one (right coronary ostium) of the unclear cases.

CONCLUSIONS

Three-dimensional TEE reduced the number of cases evaluated as unclear coronary involvement by computed tomography and 2D TEE. In patients with AAD, 3D TEE allows evaluation of the status of coronary ostia in the operating room.

Для цитирования: Sasaki Shunsuke, Watanabe Hiroyuki, Shibayama Kentaro, Mahara Keitaro, Tabata Minoru, Fukui Toshihiro, Tobaru Tetsuya, Takanashi Shuichiro, Sumiyoshi Tetsuya, Tomoike Hitonobu. Three-dimensional transesophageal echocardiographic evaluation of coronary involvement in patients with acute type A aortic dissection.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2013. DOI: 10.1016/j.echo.2013.05.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.