MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aas.13607

Медицинская библиотека · Acta anaesthesiologica Scandinavica · 2020

End-expiratory lung volume assessment using helium and carbon dioxide in an experimental model of pediatric capnoperitoneum.

Karlsson Jacob, Fodor Gergely H, Dos Santos Rocha Andre, Lin Na, Habre Walid, Wallin Mats, Hallbäck Magnus, Peták Ferenc, Lönnqvist Per-Arne

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Capnoperitoneum during laparoscopy leads to cranial shift of the diaphragm, loss in lung volume, and risk of impaired gas exchange. Infants are susceptible to these changes and bedside assessment of lung volume during laparoscopy might assist with optimizing the ventilation. Thus, the primary aim was to investigate the monitoring value of a continuous end-expiratory lung volume (EELV) assessment method based on CO2 dynamics ( EELV CO 2 ) in a pediatric capnoperitoneum model by evaluating the correlation and trending ability against helium washout (EELVHe ).

METHODS

Intra-abdominal pressure (IAP) was randomly varied between 0, 6, and 12 mm Hg with CO2 insufflation, while positive end-expiratory pressure (PEEP) levels of 3, 6, and 9 cm H2 O were randomly applied in eight anesthetized and mechanically ventilated chinchilla rabbits. Concomitant EELV CO 2 and EELVHe and lung clearance index (LCI) were obtained under each experimental condition.

RESULTS

Significant correlations were found between EELV CO 2 and EELVHe before capnoperitoneum (r = .85, P < .001), although increased IAP distorted this relationship. The negative influence of IAP was counteracted by the application of PEEP 9, which restored the correlation between EELV CO 2 and EELVHe and resulted in 100% concordance rate between the methods regarding changes in lung volume. EELVHe and LCI showed a curvilinear relationship, and an EELVHe of approximately 20 mL kg-1 , determined with a receiver operating characteristic curve, was associated with near-normal LCI values.

CONCLUSION

In this animal model of pediatric capnoperitoneum, reliable assessment of changes in EELV based on EELV CO 2 requires an open lung strategy, defined as EELV above approximately 20 mL kg-1 .

Для цитирования: Karlsson Jacob, Fodor Gergely H, Dos Santos Rocha Andre, Lin Na, Habre Walid, Wallin Mats, Hallbäck Magnus, Peták Ferenc, Lönnqvist Per-Arne. End-expiratory lung volume assessment using helium and carbon dioxide in an experimental model of pediatric capnoperitoneum.. Acta anaesthesiologica Scandinavica. 2020. DOI: 10.1111/aas.13607.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.