MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/hrt.2006.101626

Медицинская библиотека · Heart (British Cardiac Society) · 2007

Measurement of left ventricular dyssynchrony in patients with ischaemic cardiomyopathy: a comparison of real-time three-dimensional and tissue Doppler echocardiography.

Burgess Malcolm I, Jenkins Carly, Chan Jonathan, Marwick Thomas H

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Real-time three-dimensional echocardiography (RT3DE) is an alternative modality to tissue Doppler imaging (TDI) for assessment of intraventricular dyssynchrony but its role is yet to be defined.

OBJECTIVES

To (1) compare RT3DE and TDI for assessment of intraventricular dyssynchrony; (2) determine whether the two techniques agreed regarding the magnitude of dyssynchrony and identification of the site of maximal mechanical delay; and (3) investigate the reason for disagreement.

PATIENTS: 100 patients with ischaemic cardiomyopathy.

SETTING

Tertiary referral cardiac unit.

MAIN OUTCOME MEASURES: Dispersion in time interval from QRS onset to peak sustained systolic tissue velocity by TDI (SD-T(TV)) and to minimal systolic volume by RT3DE (SD-T(3D)) between 12 ventricular segments.

RESULTS

RT3DE image quality was adequate for measurement of SD-T3D in 77 (77%) patients. In the whole population, SD-T(TV) was 40 (20) ms and SD-T3D was 8.3% (3.4%). RT3DE identified a smaller proportion of patients as having significant dyssynchrony than TDI (49 (64%) patients vs 32 (42%) patients; p<0.01). The correlation between SD-T(TV) and SD-T3D was poor (r = 0.11, p = NS). There was concordance between TDI and RT3DE in identifying the site of maximal mechanical delay in 12 (16%) patients. Validating the two techniques with anatomical M-mode (AMM) as a parameter of radial timing revealed better agreement with RT3DE than with TDI (chi2 = 11.8, p = 0.001).

CONCLUSION

In patients with ischaemic cardiomyopathy, TDI and RT3DE show poor agreement for evaluating the magnitude of intraventricular dyssynchrony and the site of maximal mechanical delay. This may partly relate to their respective assessment of longitudinal versus radial timing.

Для цитирования: Burgess Malcolm I, Jenkins Carly, Chan Jonathan, Marwick Thomas H. Measurement of left ventricular dyssynchrony in patients with ischaemic cardiomyopathy: a comparison of real-time three-dimensional and tissue Doppler echocardiography.. Heart (British Cardiac Society). 2007. DOI: 10.1136/hrt.2006.101626.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.