DOI 10.1093/eurheartj/ehi046

Медицинская библиотека · European heart journal · 2004

Effect of cardiac resynchronization therapy on global and regional oxygen consumption and myocardial blood flow in patients with non-ischaemic and ischaemic cardiomyopathy.

Lindner Oliver, Vogt Jürgen, Kammeier Annett, Wielepp Peter, Holzinger Jens, Baller Detlev, Lamp Barbara, Hansky Bert, Körfer Reiner, Horstkotte Dieter, Burchert Wolfgang

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: We studied the effects of cardiac resynchronization therapy (CRT) on global and regional myocardial oxygen consumption (MVO2) and myocardial blood flow (MBF) in non-ischaemic (NICM) and ischaemic dilated cardiomyopathy (ICM).

METHODS AND

RESULTS

Thirty-one NICM and 11 ICM patients, all of them acute responders, were investigated. MVO2 and MBF were obtained by 11C-acetate PET before and after 4 months of CRT. In NICM global MVO2 and MBF did not change during CRT, while the rate pressure product (RPP) normalized MVO2 increased (P=0.03). Before CRT regional MVO2 and MBF were highest in the lateral wall and lowest in the septum. Under therapy, MVO2 and MBF decreased in the lateral wall (P=0.045) and increased in the septum (P=0.045) resulting in a more uniform distribution. In ICM, global MVO2, MBF, and RPP did not change under CRT. Regional MVO2 and MBF showed no significant changes but a similar tendency in the lateral and septal wall to that in NICM.

CONCLUSION

CRT induces changes of MVO2 and MBF on a regional level with a more uniform distribution between the myocardial walls and improved ventricular efficiency in NICM. Based on the investigated parameters, CRT appears to be more effective in NICM than in ICM.

Для цитирования: Lindner Oliver, Vogt Jürgen, Kammeier Annett, Wielepp Peter, Holzinger Jens, Baller Detlev, Lamp Barbara, Hansky Bert, Körfer Reiner, Horstkotte Dieter, Burchert Wolfgang. Effect of cardiac resynchronization therapy on global and regional oxygen consumption and myocardial blood flow in patients with non-ischaemic and ischaemic cardiomyopathy.. European heart journal. 2004. DOI: 10.1093/eurheartj/ehi046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.