Sonsmann F K, Strunk M, Gediga K, Schliemann S, Seyfarth F, Elsner P, Diepgen T L, Kutz G, John S M
Аннотация
BACKGROUND: Skin cleansers for occupational use are manufactured for different types and degrees of soiling without common, legally binding requirements for product testing. This leads to different, manufacturer-specific test methods and a lack of comparable information on skin cleansing products.
OBJECTIVES: The aim of this investigation was to validate a newly developed standardized automated cleansing device (ACiD) for in vivo evaluation of industrial skin cleansers.
METHODS: Two ACiD were tested regarding the intra- and inter-device specific reproducibility of test results.
RESULTS: Skin cleansing process carried out by the three independent washing modules which constitute an ACiD-unit and two separate ACiD-units led to highly comparable results. There was no significant difference between the washing modules or between the two separate ACiD-units detected. Only different parameter settings resulted in significantly different detergency.
CONCLUSIONS: Intra- and inter-device specific test results of an in vivo model of skin cleansing using the automated cleansing device (ACiD) were reproducible. The long-term aim is a standardized classification of occupational skin cleansing products comparing their skin cleansing effectiveness in relation to their skin irritancy. This might then provide the basis for a rational specific product selection by consumers and may be used as a tool for future product development by manufacturers.
OBJECTIVES: The aim of this investigation was to validate a newly developed standardized automated cleansing device (ACiD) for in vivo evaluation of industrial skin cleansers.
METHODS: Two ACiD were tested regarding the intra- and inter-device specific reproducibility of test results.
RESULTS: Skin cleansing process carried out by the three independent washing modules which constitute an ACiD-unit and two separate ACiD-units led to highly comparable results. There was no significant difference between the washing modules or between the two separate ACiD-units detected. Only different parameter settings resulted in significantly different detergency.
CONCLUSIONS: Intra- and inter-device specific test results of an in vivo model of skin cleansing using the automated cleansing device (ACiD) were reproducible. The long-term aim is a standardized classification of occupational skin cleansing products comparing their skin cleansing effectiveness in relation to their skin irritancy. This might then provide the basis for a rational specific product selection by consumers and may be used as a tool for future product development by manufacturers.