OBJECTIVE

Examine 11-year trends in opioid and sedative exposure and dosing practices in a level IV neonatal intensive care unit (NICU).

METHODS

This retrospective cohort study included NICU admissions from 2014 to 2024 that received at least one opioid or sedative. Temporal changes in patient characteristics, exposure patterns, continuous infusion regimen composition, and morphine and dexmedetomidine infusion rates were evaluated across three epochs (2014-2017, 2018-2021, 2022-2024).

RESULTS

Of 2055 admissions, 1060 (51.6%) encounters were analyzed. Infants admitted in later years were more premature with greater morbidity. Dexmedetomidine continuous infusion use increased fivefold (7.9% to 44.1%; p < 0.001), while morphine infusion use also increased (36.7% to 50.4%; p = 0.0021). Morphine plus dexmedetomidine became the most common continuous infusion regimen by 2022-2024 (28.7%), with higher infusion rates in combination therapy than in monotherapy.

CONCLUSION

NICU sedation strategies shifted from morphine monotherapy toward combination therapy with dexmedetomidine. Standardized, outcome-oriented guidelines and multicenter studies are needed.

Для цитирования: Lim Sin Yin, Majeedi Abrar, McAdams Ryan M. Analgesia and sedation trends in a level IV NICU, 2014-2024: Opioid and dexmedetomidine use.. Journal of perinatology : official journal of the California Perinatal Association. 2026. DOI: 10.1038/s41372-026-02586-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.