MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iae.0b013e31820b5b9b

Медицинская библиотека · Retina (Philadelphia, Pa.) · 2011

Study of intraocular pressure after 23-gauge and 25-gauge pars plana vitrectomy randomized to fluid versus air fill.

Ho Lawrence Y, Garretson Bruce R, Ranchod Tushar M, Balasubramaniam Mamtha, Ruby Alan J, Capone Antonio, Drenser Kimberly A, Williams George A, Hassan Tarek S

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To determine if a difference in intraocular pressure (IOP) exists after small-gauge pars plana vitrectomy randomized to fluid versus 80% sterile air fill.

METHODS

Ninety-two eyes undergoing 23-gauge and 25-gauge transconjunctival pars plana vitrectomy were randomized to fluid versus air fill, and IOP was measured at 5 different time points.

RESULTS

There is no difference in the mean IOP for eyes undergoing small-gauge pars plana vitrectomy randomized to fluid versus air fill after vitrectomy. Using 23-gauge instrumentation, the mean immediate and 2-hour postoperative IOPs were statistically lower than the mean preoperative IOP. The mean Postoperative Day 1 and Week 1 IOPs were statistically higher than the mean immediate postoperative IOP. Using 25-gauge instrumentation, the mean IOP was not statistically different at any time points in the 2 groups. When comparing 23-gauge with 25-gauge instrumentation, the immediate postoperative IOP was statistically lower and the rate of suture closure for sclerotomies was higher for 23-gauge vitrectomy.

CONCLUSION

When performing 23-gauge or 25-gauge pars plana vitrectomy, there was no difference in mean IOP for fluid- versus air-filled eyes. However, the mean IOP in the immediate postoperative period was statistically lower, and there was a higher rate of suture closure for 23-gauge compared with 25-gauge instrumentation.

Для цитирования: Ho Lawrence Y, Garretson Bruce R, Ranchod Tushar M, Balasubramaniam Mamtha, Ruby Alan J, Capone Antonio, Drenser Kimberly A, Williams George A, Hassan Tarek S. Study of intraocular pressure after 23-gauge and 25-gauge pars plana vitrectomy randomized to fluid versus air fill.. Retina (Philadelphia, Pa.). 2011. DOI: 10.1097/iae.0b013e31820b5b9b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.