Subconjunctival Air Leakage After Descemet's Stripping Automated Endothelial Keratoplasty(DSAEK) in a Post-Trabeculectomy Eye.

Ide Takeshi, Yoo Sonia H, Leng Theodore, O'Brien Terrence P

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report a case of subconjunctival air leakage from the anterior chamber (AC) into a trabeculectomy bleb after Descemet's stripping automated endothelial keratoplasty (DSAEK).

METHODS

An 89 year-old woman with a previous history of primary open angle glaucoma in her left eye and previous trabeculectomy with mitomycin C had DSAEK on the patient's left eye in order to treat her endothelial disease. During the DSAEK procedure, air was injected into the AC to aid in graft adherence.

RESULTS

The day after the surgery, subconjunctival air leakage from the AC into a trabeculectomy bleb was observed.

CONCLUSIONS

Although our patient did not have any complications from this leak, there exists the potential for hypotony, bleb-related infections, and dislocations of the DSAEK graft. Given the potential consequences, these patients should be monitored closely.

Для цитирования: Ide Takeshi, Yoo Sonia H, Leng Theodore, O'Brien Terrence P. Subconjunctival Air Leakage After Descemet's Stripping Automated Endothelial Keratoplasty(DSAEK) in a Post-Trabeculectomy Eye.. The open ophthalmology journal. 2009. DOI: 10.2174/1874364100903010001.