MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000093770

Медицинская библиотека · International archives of allergy and immunology · 2006

Rapid whole blood flow cytometric test to detect ICOS deficiency in patients with common variable immunodeficiency.

Bunk Robert, Dittrich Anna-Maria, Schulze Ilka, Horn Julia, Schmolke Kathrin, Volk Hans-Dieter, Wahn Volker, Höflich Conny

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Common variable immunodeficiency (CVID) is the most common primary immunodeficiency. With respect to underlying defects it comprises a heterogeneous group of deficiencies. For some patients, distinct phenotypical abnormalities have been described, e.g. partial CD40L deficiency or complete ICOS deficiency. For the diagnosis of CD40L deficiency, a rapid whole blood flow cytometric method has been described several years ago. We aimed to determine if the same method can be used to diagnose ICOS deficiency.

METHODS

Whole blood from 8 healthy volunteers was stimulated for 4 and 20 h with phorbol 12-myristate 13-acetate (PMA) and ionomycin. Induction of ICOS expression was analyzed on CD8-CD3+ lymphocytes using three-color flow cytometry. Blood from a patient with diagnosed ICOS deficiency was also analyzed.

RESULTS

Whole-blood stimulation with PMA and ionomycin for 20 h resulted in a significant induction of ICOS expression on CD8-CD3+ lymphocytes in healthy volunteers. Four-hour incubation also demonstrated ICOS upregulation but to a much lower extent. In CD8-CD3+ lymphocytes from an ICOS-deficient patient, no ICOS expression could be induced following 20 h of stimulation.

CONCLUSION

ICOS expression can be analyzed using a rapid whole blood flow cytometric test.

Для цитирования: Bunk Robert, Dittrich Anna-Maria, Schulze Ilka, Horn Julia, Schmolke Kathrin, Volk Hans-Dieter, Wahn Volker, Höflich Conny. Rapid whole blood flow cytometric test to detect ICOS deficiency in patients with common variable immunodeficiency.. International archives of allergy and immunology. 2006. DOI: 10.1159/000093770.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.