PURPOSE: To assess retinal vascular perfusion and choroidal vascularity biomarkers correlated with drusen volume and severity of age-related macular degeneration (AMD).

METHODS

Patients underwent swept-source optical coherence tomography angiography (SS-OCTA) (PlexElite-9000). Eyes with geographic atrophy or neovascular AMD were excluded. Retinal thickness, retinal perfusion including superficial (SCP) and deep capillary plexuses (DCP), foveal avascular zone (FAZ), drusen volume, choroidal thickness (ChT) and choroidal vascularity index (CVI) were assessed through the Advanced Research and Innovation Network. Linear mixed model and Spearman test were used for statistical analysis.

RESULTS

We assessed 81 eyes from 57 subjects (34 early-stage, 47 intermediate-stage AMD). The mean age was 74.95 ± 8.79 years. The mean LogMar visual acuity (VA) was 0.16 ± 0.18 (early-stage: 0.12 ± 0.17, intermediate-stage: 0.19 ± 0.18, P = 0.122). Between early and intermediate AMD, no significant differences were seen in SCP and DCP vascular perfusion (P = 0.368, 0.859, respectively), FAZ (p = 0.836) and retinal thickness within the 6-mm area (P = 0.680). Drusen volume showed a significant difference (early-stage: 0.0706 ± 0.1272, intermediate-stage: 0.2102 ± 0.2211mm3, P < 0.01). Intermediate-stage AMD had significantly lower mean ChT (266.40 ± 115.55 vs. 204.97 ± 70.69 µm, P = 0.038) and CVI (0.605 ± 0.021 vs. 0.591 ± 0.015, P = 0.004) within the 5-mm area. Drusen volume was negatively correlated with ChT (r = -0.198, P = 0.017) and CVI (r = -0.209, P = 0.029). No significant correlation was found between drusen volume and VA (r = 0.051, P = 0.143), retinal thickness (-0.03, P = 0.393), FAZ (r = -0.023, P = 0.150), SCP (r = -0.011, P = 0.307), and DCP (r = -0.022, P = 0.190).

CONCLUSION

Drusen volume, a key AMD severity marker, correlates more strongly with choroidal parameters like ChT and CVI than retinal thickness and perfusion. It may serve as a biomarker for dry AMD severity, with choroidal biomarkers showing earlier disease changes.

Для цитирования: Sadeghi Elham, Schulman Anne, Vupparaboina Sharat Chandra, Singh Sumit Randhir, Hasan Nasiq, Bollepalli Sandeep Chandra, Vupparaboina Kiran Kumar, Sahel Jose Alain, Eller Andrew W, Chhablani Jay. Correlation of retino-choroidal thickness and vascular metrics with drusen volume as a severity marker of age-related macular degeneration.. Eye (London, England). 2025. DOI: 10.1038/s41433-025-03847-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.