MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12909-025-07066-1

Медицинская библиотека · BMC medical education · 2025

The potential of artificial intelligence reading label system on the training of ophthalmologists in retinal diseases, a multicenter bimodal multi-disease study.

Wang Meng, Zhang Xiao, Li Donghui, Wei Qijie, Zhao Jianchun, Gao Xiang, Shan Tianhui, Feng Hao, Ding Guolong, Li Chan, Wu Binghui, Li Xirong, Wu Chan, Yu Weihong

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the potential of artificial intelligence reading label system on the training of ophthalmologists in a multicenter bimodal multi-disease study.

METHODS

The accuracy of 16 ophthalmologists with study duration ranging from one to nine years across multiple annotation rounds and its correlation with the number of rounds and ophthalmology study duration were analyzed. Additionally, this study evaluated the concordance between optical coherence tomography (OCT) or color fundus photography (CFP) and final case diagnosis.

RESULTS

The study involved 7777 pairs of OCT and CFP images, cases labeled with nine prevalent retinal diseases including diabetic retinopathy (DR, 2118 cases), retinal detachment (RD, 121 cases), retinal vein occlusion (RVO, 886 cases), dry age-related macular degeneration (dAMD, 549 cases), wet age-related macular degeneration (wAMD, 1023 cases), epiretinal membrane (ERM, 1061 cases), central serous retinopathy (CSC, 150 cases), macular schisis (MS, 128 cases), macular hole (MH, 86 cases) and normal fundus (1036 cases) were selected for further analysis. All images were assigned to 16 ophthalmologists over five rounds. The average diagnostic accuracy for the nine retinal diseases and normal fundus improved significantly across the five rounds (p = 0.013) and is closely correlated to the duration of ophthalmology study (p = 0.007). Furthermore, significant improvements were observed in the diagnostic accuracy of both OCT (p = 0.028) and CFP (p = 0.021) modalities as the number of rounds increased. Notably, OCT single modal diagnosis demonstrated higher consistency with the final diagnosis in cases of RD, ERM, MS, and MH compared to CFP, while CFP single modal diagnosis has higher consistency in DR, RVO and normal fundus.

CONCLUSION

The implementation of an artificial intelligence reading label system enhances the diagnostic accuracy of retinal diseases among ophthalmologists and holds potential for integration into future medical education.

Для цитирования: Wang Meng, Zhang Xiao, Li Donghui, Wei Qijie, Zhao Jianchun, Gao Xiang, Shan Tianhui, Feng Hao, Ding Guolong, Li Chan, Wu Binghui, Li Xirong, Wu Chan, Yu Weihong. The potential of artificial intelligence reading label system on the training of ophthalmologists in retinal diseases, a multicenter bimodal multi-disease study.. BMC medical education. 2025. DOI: 10.1186/s12909-025-07066-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.