MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circulationaha.119.042622

Медицинская библиотека · Circulation · 2019

Cryoballoon or Radiofrequency Ablation for Atrial Fibrillation Assessed by Continuous Monitoring: A Randomized Clinical Trial.

Andrade Jason G, Champagne Jean, Dubuc Marc, Deyell Marc W, Verma Atul, Macle Laurent, Leong-Sit Peter, Novak Paul, Badra-Verdu Mariano, Sapp John, Mangat Iqwal, Khoo Clarence, Steinberg Christian, Bennett Matthew T, Tang Anthony S L, Khairy Paul, CIRCA-DOSE Study Investigators

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Advanced generation ablation technologies have been developed to achieve more effective pulmonary vein isolation (PVI) and minimize arrhythmia recurrence after atrial fibrillation (AF) ablation.

METHODS

We randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force-guided radiofrequency ablation (CF-RF; n=115), 4-minute cryoballoon ablation (Cryo-4; n=115), or 2-minute cryoballoon ablation (Cryo-2; n=116). Follow-up was 12 months. The primary outcome was time to first documented recurrence of symptomatic or asymptomatic atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia) between days 91 and 365 after ablation or a repeat ablation procedure at any time. Secondary end points included freedom from symptomatic arrhythmia and AF burden. All patients received an implantable loop recorder.

RESULTS

One-year freedom from atrial tachyarrhythmia defined by continuous rhythm monitoring was 53.9%, 52.2%, and 51.7% with CF-RF, Cryo-4, and Cryo-2, respectively (P=0.87). One-year freedom from symptomatic atrial tachyarrhythmia defined by continuous rhythm monitoring was 79.1%, 78.2%, and 73.3% with CF-RF, Cryo-4, and Cryo-2, respectively (P=0.26). Compared with the monitoring period before ablation, AF burden was reduced by a median of 99.3% (interquartile range, 67.8%-100.0%) with CF-RF, 99.9% (interquartile range, 65.3%-100.0%) with Cryo-4, and 98.4% (interquartile range, 56.2%-100.0%) with Cryo-2 (P=0.36). Serious adverse events occurred in 3 patients (2.6%) in the CF-RF group, 6 patients (5.3%) in the Cryo-4 group, and 7 patients (6.0%) in the Cryo-2 group, with no significant difference between groups (P=0.24). The CF-RF group had a significantly longer procedure duration but significantly shorter fluoroscopy exposure (P<0.001 vs cryoballoon groups).

CONCLUSIONS

In this multicenter, randomized, single-blinded trial, CF-RF and 2 different regimens of cryoballoon ablation resulted in no difference in 1-year efficacy, which was 53% by time to first recurrence but >98% burden reduction as assessed by continuous cardiac rhythm monitoring.

CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01913522.

Для цитирования: Andrade Jason G, Champagne Jean, Dubuc Marc, Deyell Marc W, Verma Atul, Macle Laurent, Leong-Sit Peter, Novak Paul, Badra-Verdu Mariano, Sapp John, Mangat Iqwal, Khoo Clarence, Steinberg Christian, Bennett Matthew T, Tang Anthony S L, Khairy Paul, CIRCA-DOSE Study Investigators. Cryoballoon or Radiofrequency Ablation for Atrial Fibrillation Assessed by Continuous Monitoring: A Randomized Clinical Trial.. Circulation. 2019. DOI: 10.1161/circulationaha.119.042622.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.