DOI 10.1016/j.hlc.2019.07.020

Медицинская библиотека · Heart, lung & circulation · 2019

Cryoballoon Ablation in Patients With Paroxysmal Atrial Fibrillation: An Evaluation of Cohorts With and Without Structural Heart Disease.

Perego Giovanni Battista, Iacopino Saverio, Pieragnoli Paolo, Verlato Roberto, Arena Giuseppe, Molon Giulio, Rovaris Giovanni, Manfrin Massimiliano, Mantica Massimo, Senatore Gaetano, Stabile Giuseppe, Bertaglia Emanuele, Brasca Francesco, Tondo Claudio, ClinicalService 1STOP project investigators

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary vein isolation (PVI) is the most widely adopted strategy for paroxysmal atrial fibrillation (PAF) ablation. Limited evidence on acute results and late outcomes of cryoballoon (CB)-PVI in patients with structural heart disease (SHD) exist. The aim of this analysis was to compare acute procedural results and the 1-year recurrence rate of a single CB-PVI procedure in a PAF population with and without SHD.

METHOD: From April 2012 to May 2017, a total of 2,031 patients with AF underwent CB-PVI and were followed prospectively in the framework of the One Shot TO Pulmonary vein isolation (1STOP) ClinicalService project, involving 36 Italian cardiology centres. We identified patients with SHD according to criteria proposed by current ESC guidelines: left ventricular (LV) systolic or diastolic dysfunction, long-standing hypertension with LV hypertrophy, and/or other structural heart disease. Data on procedural outcomes and long-term freedom from AF recurrence were evaluated.

RESULTS

Our population consisted of 1,452 patients, of whom 282 (19.4%) were classified as having SHD. Compared to non-SHD patients, the SHD cohort was older (mean ± standard deviation, 62.9 ± 9.0 vs 58.2 ± 11.4 years; p < 0.001), was more frequently male (79.1% vs 69.8%; p < 0.002), had a higher thrombo-embolic risk (CHA2DS2VASc ≥2: 63.4% vs 40.2%; p < 0.001), had a higher body mass index (27.7 ± 3.9 vs 26.4 ± 3.9 kg/m2; p < 0.001), had a larger atrial diameter (43.8 ± 7.0 vs 40.2 ± 5.8 mm; p < 0.001), and had a lower LV ejection fraction (57.2 ± 7.7% vs 60.7 ± 6.0%; p < 0.001). At the time of ablation, 73% of patients were on class Ic or III anti-arrhythmic drugs. Procedure time (106.9 ± 41.5 vs 112.1 ± 46.8 min; p = 0.248), fluoroscopic time (28.7 ± 14.7 vs 28.6 ± 15.2 min; p = 0.819), and complication rate (3.9% vs 4.8%; p = 0.525) were not different between the SHD and non-SHD cohorts. However, the acute success rate (98.9% vs 97.7%; p = 0.016) was higher in patients with SHD. After a follow-up of 13.4 ± 12.8 months, freedom from symptomatic recurrence was 78.0% for SHD and 78.4% for non-SHD (p = 0.895). Recurrence rate was not related to either left atrial size or LVEF. In the SHD cohort, Class Ic or III anti-arrhythmic drugs treatment decreased from 70.7% of patients before ablation to 28.7% of patients after CB-PVI (p = 0.001).

CONCLUSIONS

CB-PVI was extensively applied to treat patients with PAF. Unlike previous PVI experiences, the acute success and recurrence rate after a single procedure was not related to the presence of SHD or to the degree of cardiac remodelling. Further studies are required to define whether CB-PVI has a useful role in patients with a significantly reduced ejection fraction as those patients were under-represented in the current population.

Для цитирования: Perego Giovanni Battista, Iacopino Saverio, Pieragnoli Paolo, Verlato Roberto, Arena Giuseppe, Molon Giulio, Rovaris Giovanni, Manfrin Massimiliano, Mantica Massimo, Senatore Gaetano, Stabile Giuseppe, Bertaglia Emanuele, Brasca Francesco, Tondo Claudio, ClinicalService 1STOP project investigators. Cryoballoon Ablation in Patients With Paroxysmal Atrial Fibrillation: An Evaluation of Cohorts With and Without Structural Heart Disease.. Heart, lung & circulation. 2019. DOI: 10.1016/j.hlc.2019.07.020.

Предметные рубрики MeSH