MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2017.06.020

Медицинская библиотека · Heart rhythm · 2017

Verification of a novel atrial fibrillation cryoablation dosing algorithm guided by time-to-pulmonary vein isolation: Results from the Cryo-DOSING Study (Cryoballoon-ablation DOSING Based on the Assessment of Time-to-Effect and Pulmonary Vein Isolation Guidance).

Aryana Arash, Kenigsberg David N, Kowalski Marcin, Koo Charles H, Lim Hae W, O'Neill Padraig Gearoid, Bowers Mark R, Hokanson Robert B, Ellenbogen Kenneth A, Cryo-DOSING Investigators

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

There are no recommendations on the optimal dosing for cryoablation of atrial fibrillation (Cryo-AF).

OBJECTIVE

The purpose of this study was to develop and prospectively test a Cryo-AF dosing protocol guided exclusively by time-to-pulmonary vein (PV) isolation (TT-PVI) in patients undergoing a first-time Cryo-AF.

METHODS

In this multicenter study, we examined the acute/long-term safety/efficacy of Cryo-AF using the proposed dosing algorithm (Cryo-AFDosing; n = 355) against a conventional, nonstandardized approach (Cryo-AFConventional; n = 400) in a nonrandomized fashion.

RESULTS

Acute PV isolation was achieved in 98.9% of patients in Cryo-AFDosing (TT-PVI = 48 ± 16 seconds) vs 97.2% in Cryo-AFConventional (P = .18). Cryo-AFDosing was associated with shorter (149 ± 34 seconds vs 226 ± 46 seconds; P <.001) and fewer (1.7 ± 0.8 vs 2.9 ± 0.8; P <.001) cryoapplications, reduced overall ablation (16 ± 5 minutes vs 40 ± 14 minutes; P <.001), fluoroscopy time (13 ± 6 minutes vs 29 ± 13 minutes; P <.001), left atrial dwell time (51 ± 14 minutes vs 118 ± 25 minutes; P <.001), and total procedure time (84 ± 23 minutes vs 145 ± 49 minutes; P <.001) but similar nadir balloon temperature (-47°C ± 8°C vs -48°C ± 6°C; P = .41) and total thaw time (43 ± 27 seconds vs 45 ± 19 seconds; P = .09) as compared to Cryo-AFConventional. Adverse events (2.0% vs 2.7%; P = .48), including persistent phrenic nerve palsy (0.6% vs 1.2%; P = .33) and 12-month freedom from all atrial arrhythmias (82.5% vs 78.3%; P = .14), were similar between Cryo-AFDosing and Cryo-AFConventional. However, Cryo-AFDosing was specifically associated with fewer atypical atrial flutters/tachycardias during long-term follow-up (8.5% vs 13.5%; P = .02) as well as fewer late PV reconnections at redo procedures (5.0% vs 18.5%; P <.001).

CONCLUSION

A novel Cryo-AF dosing algorithm guided by TT-PVI can help individualize the ablation strategy and yield improved procedural endpoints and efficiency as compared to a conventional, nonstandardized approach.

Для цитирования: Aryana Arash, Kenigsberg David N, Kowalski Marcin, Koo Charles H, Lim Hae W, O'Neill Padraig Gearoid, Bowers Mark R, Hokanson Robert B, Ellenbogen Kenneth A, Cryo-DOSING Investigators. Verification of a novel atrial fibrillation cryoablation dosing algorithm guided by time-to-pulmonary vein isolation: Results from the Cryo-DOSING Study (Cryoballoon-ablation DOSING Based on the Assessment of Time-to-Effect and Pulmonary Vein Isolation Guidance).. Heart rhythm. 2017. DOI: 10.1016/j.hrthm.2017.06.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.