MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-017-0236-8

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2017

Repeat procedures using the second-generation cryoballoon for recurrence of atrial fibrillation after initial ablation with conventional radiofrequency.

De Regibus Valentina, Iacopino Saverio, Abugattas Juan-Pablo, Mugnai Giacomo, Moran Darragh, Ströker Erwin, Coutino Hugo-Enrique, Takarada Ken, Choudhury Rajin, Paparella Gaetano, Umbrain Vincent, Brugada Pedro, de Asmundis Carlo, Chierchia Gian-Battista

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Pulmonary vein isolation is now widely accepted for the treatment of symptomatic atrial fibrillation refractory to antiarrhythmic drugs. However, multiple procedures are often required to significantly reduce atrial fibrillation (AF) recurrence. In the present study, we analyzed the acute results and the midterm clinical outcome of a second-generation cryoballoon ablation (CB-A) performed during repeat procedures for recurrence of AF after an initial procedure performed with conventional radiofrequency (RF).

METHODS

Consecutive patients with paroxysmal and persistent AF who underwent pulmonary vein isolation by CB-A from June 2012 in our hospital as a redo procedure after a previous pulmonary vein isolation with RF were retrospectively included in this analysis.

RESULTS

Forty-seven patients having undergone CB-A as a redo procedure were considered for our analysis. Pulmonary vein potentials were documented in 83 pulmonary veins (PV) that were all successfully re-isolated using the CB-A. Transient phrenic nerve palsy was the only complication occurring in our study cohort. After a mean follow-up of 15 ± 8 months, 76.6% of patients were free from recurrence of atrial fibrillation. If taking into consideration a 3-month blanking period, 83% of patients were free from recurrence. The success rate in patients affected by paroxysmal AF was 87% at final follow-up following the blanking period.

CONCLUSIONS

The second-generation CB is effective in treating recurrence of AF after a previous ablation performed with conventional RF. Considering a 3-month blanking period, 83% of the patients were free from any atrial tachycardia recurrence during a 15-month follow-up. This approach proved particularly successful in patients affected by paroxysmal AF.

Для цитирования: De Regibus Valentina, Iacopino Saverio, Abugattas Juan-Pablo, Mugnai Giacomo, Moran Darragh, Ströker Erwin, Coutino Hugo-Enrique, Takarada Ken, Choudhury Rajin, Paparella Gaetano, Umbrain Vincent, Brugada Pedro, de Asmundis Carlo, Chierchia Gian-Battista. Repeat procedures using the second-generation cryoballoon for recurrence of atrial fibrillation after initial ablation with conventional radiofrequency.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2017. DOI: 10.1007/s10840-017-0236-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.