MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.15821

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2023

Differential gap location after radiofrequency versus cryoballoon pulmonary vein isolation: Insights from a randomized trial with protocol-mandated repeat procedure.

Sørensen Samuel K, Johannessen Arne, Worck René, Hansen Morten L, Ruwald Martin H, Hansen Jim

Протокол клинического исследованияСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Reconnections to pulmonary vein (PV) triggers of atrial fibrillation (AF) are the primary cause of AF recurrence after PV isolation (PVI) with radiofrequency (RF) or cryoballoon catheter ablation (CRYO), but method-specific contributions to PV reconduction pattern and conductive gap location are incompletely understood.

METHODS

The objective of this radiofrequency versus cryoballoon catheter ablation for paroxysmal atrial fibrillation substudy was to determine procedure-specific patterns of PV reconduction in a randomized population with protocol-mandated repeat procedures, irrespective of AF recurrence. Each PV was assessed in turn and PV reconnection sites were identified by high-density electroanatomical mapping and locating the earliest activation site. Gap locations were verified by PV re-isolation.

RESULTS

In 98 patients, 81% versus 76% previously isolated PVs remained isolated after CRYO versus RF (risk ratio [RR]: 1.06; 95% confidence interval [CI]: 0.96-1.18; p = .28). There were no significant differences for any PV: left superior PV: 90% versus 80%; left inferior PV: 80% versus 78%; right superior PV: 81% versus 80%, and right inferior PV: 76% versus 73%. For each reconnected PV, 34% of ipsilateral PVs were also reconnected after CRYO compared with 64% after RF (RR: 0.54; 95% CI: 0.32-0.90; p = .01). After RF, gaps were clustered by the carina and adjacent segments, whereas they were more heterogeneously distributed after CRYO.

CONCLUSION

Although RF and CRYO produce similar proportions of durably isolated PVs, gap locations appear to develop in procedure-specific patterns. After RF, ipsilateral PV reconduction is more frequent and gap sites cluster by the carina, suggesting that this region should be selectively ablated for more durable PVI.

Для цитирования: Sørensen Samuel K, Johannessen Arne, Worck René, Hansen Morten L, Ruwald Martin H, Hansen Jim. Differential gap location after radiofrequency versus cryoballoon pulmonary vein isolation: Insights from a randomized trial with protocol-mandated repeat procedure.. Journal of cardiovascular electrophysiology. 2023. DOI: 10.1111/jce.15821.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.