MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-022-01393-9

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022

Impact of pulmonary veins anatomy on the outcomes of radiofrequency ablation for paroxysmal atrial fibrillation in the era of contact force-sensing ablation catheters.

Benali Karim, Lai Van Duc, Hammache Nefissa, Magnin-Poull Isabelle, de Chillou Christian, Sellal Jean-Marc

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary vein (PV) isolation (PVI) has become the cornerstone of atrial fibrillation (AF) ablation in patients with paroxysmal AF (PAF). PVI durability is influenced by many factors including PVs anatomy. Data regarding the influence of PVs anatomical variations on the outcomes of PAF ablation in the era of contact force-sensing ablation catheters are scarce and contradictory.

METHODS

Consecutive patients referred to our center for a first ablation of PAF using radiofrequency (RF) were included. PVs anatomy was classified into 3 groups: typical anatomy (4 distinct veins), left common ostium (LCO), and right accessory PV (RAPV). The primary outcome was recurrence of atrial arrhythmia episode during a 12-month follow-up after ablation.

RESULTS

Two hundred twenty-three patients were included (mean age 58.4 ± 10.8 years and 70.9% male). Among this cohort, 141 patients (63.2%) had typical PV anatomy, 53 (23.8%) had a LCO, and 29 (13.0%) had a RAPV. The existence of a RAPV was not associated with a higher rate of AF recurrences (22 (14.3%) vs. 7 (10.1%), p = 0.519). After multivariate analysis, the presence of an LCO did not appear to be associated with the AF recurrence rate at 12 months (OR = 1.69, 95%CI 0.95-2.49, p = 0.098). Maintenance of antiarrhythmic drugs after ablation was the only factor independently associated with a decreased risk of AF recurrence at 12 months (OR = 0.76, 95%CI 0.60-0.97, p = 0.046).

CONCLUSION

This study suggests that the presence of an LCO or a RAPV is not associated with a higher rate of AF recurrence at 12 months after radiofrequency PVI using contact force-sensing catheters in PAF patients.

Для цитирования: Benali Karim, Lai Van Duc, Hammache Nefissa, Magnin-Poull Isabelle, de Chillou Christian, Sellal Jean-Marc. Impact of pulmonary veins anatomy on the outcomes of radiofrequency ablation for paroxysmal atrial fibrillation in the era of contact force-sensing ablation catheters.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2022. DOI: 10.1007/s10840-022-01393-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.