DOI 10.1111/pace.14582

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2022

Impact of high frequency stimulation to confirm a complete box isolation in catheter ablation of non-paroxysmal atrial fibrillation.

Kato Kazuo, Hasegawa Shin, Kikuchi Shun, Uehara Yukihiro, Ishiguro Nobuo, Tanaka Akimitsu, Tominaga Shimpei, Goto Hiroko, Shibata Norihisa, Kametani Ryosuke

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Pulmonary vein (PV) isolation (PVI) including the left atrial posterior wall (LAPW) (Box-PVI) is proposed as an additional strategy for non-paroxysmal atrial fibrillation (NPAF), however, the efficacy remains controversial. The more reliable and durable the Box-PVI we can create, the better the rhythm outcomes might be than with a conventional PVI alone. This study focused on the potential exit conduction of the box lesion and investigated whether the conventional Box-PVI would be sufficient.

METHODS AND

RESULTS

We enrolled 350 consecutive patients with NPAF that underwent a conventional encircling Box-PVI and examined whether latent exit conduction and dormant "exit" conduction independently remained on the LAPW and in the PVs using high frequency stimulation (HFS) and an adenosine triphosphate (ATP) injection. All electrograms inside the box lesion were eliminated in all cases, however, HFS inside the box propagated outward in 23 cases (6.6%) without any exit conduction by conventional burst stimulation, and 24 cases (6.9%) exhibited only dormant "exit" conduction of the LAPW. Additional ablation where positive HFSs were observed created a complete bidirectional Box-PVI in 43 (41.3%) of the cases without a first pass Box-PVI. The recurrence rates depended on the groups classified according to the HFS response.

CONCLUSION

HFS delivered with an ATP injection on the LAPW and in the PVs following a Box-PVI could not only elucidate true exit block but also identified possible incomplete lesions or connections outside the ablation line, whose elimination could achieve a complete Box-PVI leading to a better rhythm outcome.

Для цитирования: Kato Kazuo, Hasegawa Shin, Kikuchi Shun, Uehara Yukihiro, Ishiguro Nobuo, Tanaka Akimitsu, Tominaga Shimpei, Goto Hiroko, Shibata Norihisa, Kametani Ryosuke. Impact of high frequency stimulation to confirm a complete box isolation in catheter ablation of non-paroxysmal atrial fibrillation.. Pacing and clinical electrophysiology : PACE. 2022. DOI: 10.1111/pace.14582.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.