Long-term outcomes of a time to isolation - based strategy for cryoballoon ablation compared to radiofrequency ablation in patients with symptomatic paroxysmal atrial fibrillation.

Wei Yue, Chen Lin, Cao Jiang, Liu Shaowen, Ling Tianyou, Huang Xinmiao, Zhou Genqing, Lin Changjian, Xie Yun, Bao Yangyang, Luo Qingzhi, Ye Jiawen, Zhang Ning, Jin Qi, Wu Liqun

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Cryoballoon ablation (CBA) is one of the most commonly used technologies designed for pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF), although the dosing of CBA remains controversial. We evaluated the long-term efficacy and safety of a novel individualized strategy of CBA compared to radiofrequency ablation (RFA) for patients with PAF.

METHODS

In this observational study, symptomatic patients with drug-refractory paroxysmal AF were prospectively consented and enrolled in four centers, being assigned either to the CBA or RFA arm for ablation. In the CBA group, we used a time to isolation (TTI) - based dosing protocol. The primary endpoint was the recurrence of atrial arrhythmia >30 s following a 90-day blanking period. The secondary endpoint was procedure-related complications and procedure parameters.

RESULTS

A total of 500 patients were recruited in either the CBA group (n = 247) or the RFA group (n = 253) between January 2017 and July 2018. After a median follow-up of 778 days, the atrial tachyarrhythmia-free survival was 71.7% in the CBA group and 67.0% in the RFA group. CBA and RFA displayed similar major or minor complication occurrence, while the former had a significantly shorter procedure duration (82.5 min vs. 141.1 min, p < .001) and left atrial dwell time (60.1 min vs. 109.9 min, p < .001) but longer fluoroscopy exposure (13.8 min vs. 8.1 min, p < .001).

CONCLUSION

Compared to RFA, our TTI-based CBA dosing protocol showed comparable efficacy and safety, with a significantly reduced procedure duration in patients with PAF.

Для цитирования: Wei Yue, Chen Lin, Cao Jiang, Liu Shaowen, Ling Tianyou, Huang Xinmiao, Zhou Genqing, Lin Changjian, Xie Yun, Bao Yangyang, Luo Qingzhi, Ye Jiawen, Zhang Ning, Jin Qi, Wu Liqun. Long-term outcomes of a time to isolation - based strategy for cryoballoon ablation compared to radiofrequency ablation in patients with symptomatic paroxysmal atrial fibrillation.. Pacing and clinical electrophysiology : PACE. 2022. DOI: 10.1111/pace.14556.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.