MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.15564

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2022

Stand-alone Focal Impulse and Rotor Modulation (FIRM) ablation versus second-generation cryoballoon pulmonary vein isolation for paroxysmal atrial fibrillation.

Tilz Roland R, Yalin Kivanc, Lyan Evgeny, Heeger Christian-Hendrik, Schlüter Michael, Fink Thomas, Sciacca Vanessa, Liosis Spyridon, Kuck Karl-Heinz, Popescu Sorin Ștefan, Mortensen Kai, Meyer-Saraei Roza, Eitel Charlotte, Vogler Julia

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Focal Impulse and Rotor Modulation (FIRM) guided catheter ablation aiming at stable rotors has been investigated as a treatment option in patients with atrial fibrillation (AF). The objective of this study was to compare the safety and efficacy of FIRM-guided ablation with second-generation cryoballoon pulmonary vein isolation (CB2-PVI) in paroxysmal AF.

METHODS

Consecutive patients (n = 22, mean age 60 ± 11 years, 59.1% of males) who were treated with a stand-alone FIRM-guided ablation were included in this retrospective single-center study. Procedural data and arrhythmia-free survival at 12 months were compared with n = 86 consecutive patients (mean age 62 ± 13 years, 62.4% of males) who received de-novo CB2-PVI.

RESULTS

Median procedure duration was significantly longer in the FIRM group than in the CB2-PVI group (152 [IQR 120-176] minutes vs. 122 [110-145] minutes; p = .031). One patient (1.2%) in the CB2-PVI group and five patients (22.7%) in the FIRM group had vascular access complications. Atrial tachyarrhythmias recurred in 15 patients in the FIRM group and 11 in the CB2-PVI group. Kaplan-Meier estimation of single-procedure arrhythmia-free survival at 12 months was 25% (95% confidence interval [CI] 6%-44%) in the FIRM group and 87% (95% CI 78%-96%) in the CB2-PVI group (p < .001). Repeat ablations were performed in 14/20 (70.0%) patients in the FIRM group and in 12/85 (14.1%) in the CB2-PVI group (p < .001).

CONCLUSION

De novo ablation of AF using FIRM-guided AF ablation results in shorter arrhythmia-free survival after 12 months compared to CB2-PVI and a need for repeat ablation in the majority of patients to achieve stable sinus rhythm.

Для цитирования: Tilz Roland R, Yalin Kivanc, Lyan Evgeny, Heeger Christian-Hendrik, Schlüter Michael, Fink Thomas, Sciacca Vanessa, Liosis Spyridon, Kuck Karl-Heinz, Popescu Sorin Ștefan, Mortensen Kai, Meyer-Saraei Roza, Eitel Charlotte, Vogler Julia. Stand-alone Focal Impulse and Rotor Modulation (FIRM) ablation versus second-generation cryoballoon pulmonary vein isolation for paroxysmal atrial fibrillation.. Journal of cardiovascular electrophysiology. 2022. DOI: 10.1111/jce.15564.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.