MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/jcma.0000000000000709

Медицинская библиотека · Journal of the Chinese Medical Association : JCMA · 2022

Dynamic changes in signal-averaged P wave after catheter ablation of atrial fibrillation.

Yugo Dony, Kuo Ming-Jen, Hu Yu-Feng, Liu Chih-Min, Lin Yenn-Jiang, Chang Shih-Lin, Lo Li-Wei, Chao Tze-Fan, Chung Fa-Po, Liao Jo-Nan, Chang Ting-Yung, Lin Chin-Yu, Tuan Ta-Chuan, Kuo Ling, Liu Shin-Huei, Ton An Nu-Khanh, Chhay Chheng, Elimam Ahmed, Chen Shih-Ann

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The comprehensive surveillance for interval changes in signal-averaged P-wave (SAPW) after pulmonary vein isolation (PVI) remains lacking. We aimed to analyze the SAPW parameters before and after PVI and explored their link to the left atrial electrical properties.

METHODS

Eighteen patients with paroxysmal atrial fibrillation receiving primary catheter ablation were enrolled. SAPW parameters, including root mean square voltages in the last 40, 30, and 20 ms (RMS40, RMS30, and RMS20, respectively), the total P-wave (RMSt), the integral of P-wave potentials (Int-p), and P-wave duration (fPWD), were measured before and after PVI and correlated to the left atrial activation time (LAT) and mean left atrial voltage (LAV) from electro-anatomical mapping.

RESULTS

Compared with the SAPW before PVI, fPWD (before vs after PVI: 144.1 ± 5.2 vs 135.1 ± 11.9 ms, p = 0.02), Int-p (687.4 ± 173.1 vs 559 ± 202.5 mVms, p = 0.01), and RMSt (6.44 ± 1.3 vs 5.44 ± 2.0 mV, p = 0.04) all decreased after PVI. RMS20, RMS30, and RMS40 showed no significant difference. Similarly, LAT (97.5 ± 9.3 vs 90.5 ± 9.3 ms, p = 0.008) and LAV (1.37 ± 0.27 vs 0.96 ± 0.31 mV, p = 0.001) decreased after PVI. Although consistent changes after PVI were observed between SAPW parameters and LAT or LAV, no linear correlation was observed among them.

CONCLUSION

The consistent changes in SAPW and left atrial electrical properties after PVI suggest that SAPW may be used as a noninvasive tool to monitor the responses to PVI.

Для цитирования: Yugo Dony, Kuo Ming-Jen, Hu Yu-Feng, Liu Chih-Min, Lin Yenn-Jiang, Chang Shih-Lin, Lo Li-Wei, Chao Tze-Fan, Chung Fa-Po, Liao Jo-Nan, Chang Ting-Yung, Lin Chin-Yu, Tuan Ta-Chuan, Kuo Ling, Liu Shin-Huei, Ton An Nu-Khanh, Chhay Chheng, Elimam Ahmed, Chen Shih-Ann. Dynamic changes in signal-averaged P wave after catheter ablation of atrial fibrillation.. Journal of the Chinese Medical Association : JCMA. 2022. DOI: 10.1097/jcma.0000000000000709.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.