MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.healun.2012.09.024

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2012

Patients with low compared with high body mass index gain more weight after implantation of a continuous-flow left ventricular assist device.

Emani Sitaramesh, Brewer Robert J, John Ranjit, Slaughter Mark S, Lanfear David E, Ravi Yazhini, Sundareswaran Kartik S, Farrar David J, Sai-Sudhakar Chittoor B

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Patterns of weight change after implantation of a continuous-flow left ventricular assist device (CF-LVAD) can affect transplant candidacy and may influence outcomes. We evaluated changes in weight over a 24-month period from a national LVAD clinical trial database.

METHODS

A retrospective analysis was performed of 896 patients enrolled into the HeartMate II Clinical trials for bridge-to-transplant and destination therapy from March 2005 to January 2009. The patients were divided into 4 groups: underweight (body mass index [BMI] <18.5 [kg/m(2)]); normal (BMI 18.5 to 29.9); obese (BMI 30 to 34.9); and extremely obese (BMI ≥ 35). Baseline BMI was compared with BMI at 6 months and 24 months after implant. BMI change >10% of baseline was considered clinically significant.

RESULTS

At 6 months, underweight and normal-weight patients had significant increases in BMI, with effects sustained up to 24 months (p < 0.01). Underweight patients gained weight most often, with 75% showing clinically meaningful weight gain at 24 months. Obese and extremely obese patients, in contrast, did not experience weight change over the same period. Pre-albumin levels improved from baseline to 6 months in all patients.

CONCLUSIONS

Underweight and normal-weight patients had an increase in BMI after LVAD implantation, and these changes persisted through 24 months. The BMIs of obese and extremely obese patients remained unchanged. Nutritional status improved in all groups.

Для цитирования: Emani Sitaramesh, Brewer Robert J, John Ranjit, Slaughter Mark S, Lanfear David E, Ravi Yazhini, Sundareswaran Kartik S, Farrar David J, Sai-Sudhakar Chittoor B. Patients with low compared with high body mass index gain more weight after implantation of a continuous-flow left ventricular assist device.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2012. DOI: 10.1016/j.healun.2012.09.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.