The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2009
Increased number of circulating progenitor cells after implantation of ventricular assist devices.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Manginas Athanassios, Tsiavou Anastasia, Sfyrakis Petros, Giamouzis Gregory, Tsourelis Loukas, Leontiadis Evangelos, Degiannis Dimitrios, Cokkinos Dennis V, Alivizatos Petros A
Аннотация
BACKGROUND: Bone marrow-derived circulating progenitor cells possess tissue repair potential, improving perfusion, left ventricular remodeling, and contractility in experimental models. We quantified and investigated the kinetics of 4 circulating progenitor cell sub-populations on the basis of CD34, CD133, and vascular endothelial growth factor receptor-2 (VEGFR-2) antigen expression.
METHODS: CD34+, CD34+/CD133+/VEGFR-2-, CD34+/CD133+/VEGFR-2+, and CD34+/CD133-/VEGFR-2+ cells were counted in 10 male patients with end-stage congestive heart failure. Five underwent left ventricular/biventricular assist device (LVAD/BiVAD) implantation (VAD group), and 5 were ineligible for VAD implantation (no-VAD group). Peripheral blood was collected at 3 time points for each patient: before, 15, and 60 days after VAD placement in the VAD group and at the same time points in the no-VAD group. Purified CD34+ cells were stained with anti-CD34, anti-CD133, and anti-VEGFR-2 monoclonal antibodies and analyzed by flow cytometry. Serum levels of granulocyte-colony stimulating factor (G-CSF), interleukin-8, vascular endothelial growth factor-alpha (VEGF-alpha), and B-type natriuretic peptide (BNP) were also measured.
RESULTS: In the VAD group the number of CD34+ cells/ml of blood tended to increase, from 159.6 +/- 137.0 at baseline to 428.9 +/- 224.3 at 15 days, and decreased to 343.8 +/- 165.7 at 60 days (p = 0.05 vs no-VAD group). In the other 3 cell populations, no significant differences occurred over time or between groups. A significant interaction between BNP levels and VAD status was observed (p = 0.005): BNP levels decreased over time in VAD patients vs no-VAD patients. G-CSF levels tended to decrease over time in both groups, but without a significant difference (p = 0.3). Serum levels of interleukin-8 and VEGF-alpha over time or between VAD and no-VAD patients were not significantly different.
CONCLUSIONS: After VAD implantation, a transient increase occurs in the number of circulating CD34+ cells, in parallel to a reduction in BNP levels. Release of these cells from the bone marrow may contribute to the improvement of tissue perfusion and cardiac recovery occasionally seen after VAD placement.
METHODS: CD34+, CD34+/CD133+/VEGFR-2-, CD34+/CD133+/VEGFR-2+, and CD34+/CD133-/VEGFR-2+ cells were counted in 10 male patients with end-stage congestive heart failure. Five underwent left ventricular/biventricular assist device (LVAD/BiVAD) implantation (VAD group), and 5 were ineligible for VAD implantation (no-VAD group). Peripheral blood was collected at 3 time points for each patient: before, 15, and 60 days after VAD placement in the VAD group and at the same time points in the no-VAD group. Purified CD34+ cells were stained with anti-CD34, anti-CD133, and anti-VEGFR-2 monoclonal antibodies and analyzed by flow cytometry. Serum levels of granulocyte-colony stimulating factor (G-CSF), interleukin-8, vascular endothelial growth factor-alpha (VEGF-alpha), and B-type natriuretic peptide (BNP) were also measured.
RESULTS: In the VAD group the number of CD34+ cells/ml of blood tended to increase, from 159.6 +/- 137.0 at baseline to 428.9 +/- 224.3 at 15 days, and decreased to 343.8 +/- 165.7 at 60 days (p = 0.05 vs no-VAD group). In the other 3 cell populations, no significant differences occurred over time or between groups. A significant interaction between BNP levels and VAD status was observed (p = 0.005): BNP levels decreased over time in VAD patients vs no-VAD patients. G-CSF levels tended to decrease over time in both groups, but without a significant difference (p = 0.3). Serum levels of interleukin-8 and VEGF-alpha over time or between VAD and no-VAD patients were not significantly different.
CONCLUSIONS: After VAD implantation, a transient increase occurs in the number of circulating CD34+ cells, in parallel to a reduction in BNP levels. Release of these cells from the bone marrow may contribute to the improvement of tissue perfusion and cardiac recovery occasionally seen after VAD placement.
Предметные рубрики MeSH
AC133 AntigenAdultAgedAntigens, CDAntigens, CD34Case-Control StudiesCell DifferentiationCell ProliferationGlycoproteinsGranulocyte Colony-Stimulating FactorHeart FailureHeart-Assist DevicesHematopoietic Stem CellsHumansInterleukin-8MaleMiddle AgedNatriuretic Peptide, BrainPeptidesVascular Endothelial Growth Factor AVascular Endothelial Growth Factor Receptor-2