DOI 10.1097/mnm.0000000000000876
Assessment of normal reference values for thyroid uptake of technetium-99m pertechnetate in a single centre UK population.
Аннотация
OBJECTIVE
This study aims to explore the normal reference values for thyroid uptake of technetium-99m (Tc) pertechnetate in a UK population.
PATIENTS AND
METHODS
A retrospective review of 60 euthyroid patients who underwent thyroid imaging with Tc pertechnetate between January 2012 to April 2014 as part of dual-tracer subtraction parathyroid scintigraphy. Tc pertechnetate thyroid uptake values were determined for each patient. Medical records and biochemical thyroid function tests were reviewed to ensure that all patients were not on medication that could affect thyroid function and they were both clinically and biochemically euthyroid 6 months before and following the scan.
RESULTS
Median and interquartile uptake range of Tc pertechnetate in euthyroid patients were 0.9 and 0.5-1.4%, respectively. The normal reference range in the study population was 0.2-2.0%. Thyroid uptake inversely correlated with age in females (r=-0.40, P=0.04), males (r=-0.50, P=0.04), and whole group (r=-0.40, P=0.002).
CONCLUSION
The calculated normal reference range in this study was found to be less than that used in our own and many other UK institutions. The results demonstrate the importance of periodic evaluation of normal uptake values and provide support for prospective studies defining the normal reference range to be performed.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.