MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d6ra05561c

Медицинская библиотека · RSC advances · 2026

Development and validation of a green spectrofluorimetric method using a rhodamine 6G probe and FCCCD-optimized dispersive liquid-liquid microextraction for tenuazonic acid surveillance in dried figs.

Redwan Fotoon F, Serag Ahmed, Abdelazim Ahmed H, Abduljabbar Maram H, Alqahtani Arwa Sultan, Alosaimi Manal E, Almutairi Farooq M, Almalki Atiah H

СтатьяПеревод пока не подготовлен

Аннотация

Tenuazonic acid (TeA) is a major Alternaria mycotoxin frequently contaminating dried figs, yet its routine surveillance remains constrained by reliance on costly chromatographic instrumentation. To address this analytical gap, a novel "turn-off" spectrofluorimetric method was developed for TeA determination in dried fig samples using rhodamine 6G as a cationic xanthene fluorescent probe. Given the complexity of the sugar-rich matrix, dispersive liquid-liquid microextraction was first optimized through a face-centered central composite design coupled with Derringer's desirability function. Optimal conditions comprised 350 µL of 1-octanol as extractant, 700 µL of acetonitrile as disperser, pH 3.3, and 5% (w/v) ammonium sulfate, yielding an experimental recovery of 95.23% ± 1.48%. Subsequently, spectral characterization demonstrated strong native fluorescence of rhodamine 6G at 555 nm (λ ex 526 nm), progressively quenched in the presence of TeA. Multi-temperature Stern-Volmer analysis, Job's continuous variation method, and thermodynamic evaluation confirmed a static quenching mechanism involving 1 : 1 ground-state complex formation. Comprehensive validation demonstrated linearity across 20-4000 µg kg-1 (R 2 = 0.9981), with an LOQ of 19.2 µg kg-1. Mean recoveries ranged from 94.9% to 99.7%, intra- and inter-day precision remained below 11%, expanded measurement uncertainty was within ±22.4%, and matrix effects were negligible (-3.4%). Application to 60 Egyptian dried fig samples revealed widespread contamination (90% incidence; mean 726 ± 483 µg kg-1), with 26.7% exceeding the 1000 µg kg-1 indicative level. Green chemistry evaluation using AGSA-Prep (65%), WECA (81%), and EPPI (84.2) confirmed the method's sustainability, establishing it as a practical alternative to LC-MS/MS for routine TeA surveillance in resource-limited laboratories.

Для цитирования: Redwan Fotoon F, Serag Ahmed, Abdelazim Ahmed H, Abduljabbar Maram H, Alqahtani Arwa Sultan, Alosaimi Manal E, Almutairi Farooq M, Almalki Atiah H. Development and validation of a green spectrofluorimetric method using a rhodamine 6G probe and FCCCD-optimized dispersive liquid-liquid microextraction for tenuazonic acid surveillance in dried figs.. RSC advances. 2026. DOI: 10.1039/d6ra05561c.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.