MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0305-4179(06)80015-x

Медицинская библиотека · Burns : journal of the International Society for Burn Injuries · 1994

Comparison of high-frequency jet to conventional mechanical ventilation in the treatment of severe smoke inhalation injury.

Nieman G F, Cigada M, Paskanik A M, Del Pozzo J, Clark W R, Camporesi E M, Hakim T S

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The pathophysiology of smoke inhalation includes surfactant inhibition and pulmonary vascular injury leading to a high permeability pulmonary oedema. It has been shown in surfactant deficient animal models that methods of ventilation (i.e. high-frequency ventilation - HFV) avoiding a large pressure excursion (i.e. pressure change from end expiration to peak inspiration) improves oxygenation and decreases hyaline membrane formation. Therefore, we compared HFV with conventional mechanical ventilation (CMV) on lung function in an acute animal model of smoke inhalation (SI). Mongrel dogs were anaesthetized, surgically prepared for haemodynamic and blood gas monitoring, and placed on either CMV (n = 6) or HFV (n = 7). Following baseline (BL) measurements both groups were ventilated with wood smoke for 10 min. Ventilator settings were not adjusted from baseline following smoke inhalation in either groups; positive and expiratory pressure (PEEP, approximately 6 mmHg) was added in both groups following smoke exposure. At the conclusion of the study (4 h postsmoke inhalation) lung samples were taken for surfactant function and lung water measurements. Smoke inhalation immediately increased the A-a gradient (CMV-BL = 6.9 +/- 2.4 to CMV-SI = 77.3 +/- 1.9; HFV-BL = 10.5 +/- 2.7; HFV-SI = 72.8 +/- 3.7 mmHg), venous admixture (CMV-BL = 6.9 +/- 2.8 to CMV-SI 69.8 +/- 6.6; HFV-BL = 7 +/- 1.7 to HFV-SI = 60.4 +/- 7.9 per cent) and decreased Pao2 (CMV-BL = 110 +/- 3.4 to CMV-SI = 28 +/- 3.5; HFV-BL = 103 +/- 3.6 to HFV-SI = 31 +/- 1.7 mmHg) to a similar level in both groups.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Nieman G F, Cigada M, Paskanik A M, Del Pozzo J, Clark W R, Camporesi E M, Hakim T S. Comparison of high-frequency jet to conventional mechanical ventilation in the treatment of severe smoke inhalation injury.. Burns : journal of the International Society for Burn Injuries. 1994. DOI: 10.1016/s0305-4179(06)80015-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.