MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/cclm-2023-0216

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2023

Analysis of a second-tier test panel in dried blood spot samples using liquid chromatography-tandem mass spectrometry in Catalonia's newborn screening programme.

Pajares-García Sonia, González de Aledo-Castillo José Manuel, Flores-Jiménez José Eduardo, Collado Tatiana, Pérez Judit, Paredes-Fuentes Abraham José, Argudo-Ramírez Ana, López-Galera Rosa María, Prats Blanca, García-Villoria Judit

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Acylcarnitine and amino acid analyses of dried blood spot (DBS) samples using tandem mass spectrometry in newborn screening (NBS) programmes can generate false positive (FP) results. Therefore, implementation of second-tier tests (2TTs) using DBS samples has become increasingly important to avoid FPs. The most widely used 2TT metabolites include methylmalonic acid, 3-hydroxypropionic acid, methylcitric acid, and homocysteine.

METHODS

We simultaneously measured 46 underivatised metabolites, including organic acids, acylglycine and acylcarnitine isomers, homocysteine, and orotic acid, in DBS samples using tandem mass spectrometry. To validate this method, we analysed samples from 147 healthy newborns, 160 patients with genetic disorders diagnosed via NBS, 20 patients with acquired vitamin B12 deficiency, 10 newborns receiving antibiotic treatment, and nine external quality control samples.

RESULTS

The validation study revealed that 31 metabolites showed good analytical performance. Furthermore, this method detected key metabolites for all diseases associated with increased levels of the following acylcarnitines: C3, C4, C5, C4DC/C5OH, and C5DC. The sensitivity of this method to detect all diseases was 100 %, and the specificity was 74-99 %, except for glutaric aciduria type 1. This method can also be used to diagnose mitochondrial fatty acid β-oxidation disorders (FAODs) and urea cycle defects (UCDs).

CONCLUSIONS

We have described a 2TT panel of 31 metabolites in DBS samples based on an easy and rapid method without derivatisation. Its implementation allowed us to distinguish between different organic acidurias, some FAODs, and UCDs. This new strategy has increased the efficiency of our NBS programme by reducing FP and false negative results, second sample requests, and the time required for diagnosis.

Для цитирования: Pajares-García Sonia, González de Aledo-Castillo José Manuel, Flores-Jiménez José Eduardo, Collado Tatiana, Pérez Judit, Paredes-Fuentes Abraham José, Argudo-Ramírez Ana, López-Galera Rosa María, Prats Blanca, García-Villoria Judit. Analysis of a second-tier test panel in dried blood spot samples using liquid chromatography-tandem mass spectrometry in Catalonia's newborn screening programme.. Clinical chemistry and laboratory medicine. 2023. DOI: 10.1515/cclm-2023-0216.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.