OBJECTIVES

Data on anesthetic proceedings during cardiac implantable electronic device (CIED) implant procedures are scarce and it remains unclear whether anesthetic care is still required in selected patients.

METHODS

In this retrospective, single center study we assessed the prevalence of intraoperative anesthetic management comprising anesthetic standby, sedation or general anesthesia as well as anesthetic and procedural complications. We analyzed pre-existing and perioperative risk factors related to procedure-related adverse outcome such as perioperative cardiopulmonary resuscitation (CPR) and 30-day mortality in a uni- and multivariable analysis.

RESULTS

In total, PM and ICD insertion were performed in up to 85% and 58% under anesthetic standby, with an increasing tendency over time.Overall, Cardiopulmonary resuscitation (CPR) was required in 59 patients. Acute heart failure (AHF) was the only independent pre-existing risk factor for CPR and for 30-day mortality. Sedation and general anesthesia had a significantly increased odds ratio for CPR compared to anesthetic standby. The risk for CPR significantly decreased during the study period.

CONCLUSIONS

Over the years anesthetic practice during CIED implant procedures shifted from mixed anesthetic proceedings to mainly standby duties. The prevalence of complications and emergency measures is low, however not uncommon. Accordingly, the presence of an anesthesiologist should be further guaranteed when sedatives were titrated and in AHF patients. However, in patients receiving local anesthetic infiltration only, it seems safe to perform CIED implant procedures without anesthetic standby.

Для цитирования: Veraar Cecilia, Dimitrov Kamen, Kappel Sabine, Wuthe Sophie J, Veraar Clarence J, Fischer Arabella, Worf Isabella, Mouhieddine Mohamed, Mandroiu Luana, Moser Bernhard, Patrick Mayr N, Khazen Cesar, Tschernko Edda, Hiesmayr Michael J. Anesthetic practice during cardiac implantable electronic device implant procedures: A retrospective, single-center study.. International journal of cardiology. Heart & vasculature. 2023. DOI: 10.1016/j.ijcha.2023.101312.