DOI 10.1016/j.healun.2023.06.013
Adverse events after left ventricular assist device implantation linked to psychosocial risk in women and men.
Аннотация
BACKGROUND
Reasons for women's increased probability to experience adverse events (AEs) after left ventricular assist device (LVAD) implantation compared with men's remain uncertain. We explored the role of psychosocial risk in the experience of AEs in women and men.
METHODS
INTERMACS patients receiving a primary continuous-flow LVAD between July 2006 and December 2017, median follow-up 13.6 months, were included (n = 20,123, 21.3% women). Time-to-event was calculated with cumulative incidence functions for 10 types of AEs separately (e.g., infection, device malfunction), each time accounting for the competing outcomes death, heart transplant, and device explant due to recovery. Event-specific Cox proportional hazard models were run with a binary psychosocial risk variable (including substance abuse, psychiatric diagnosis, limited social support, limited cognition, repeated noncompliance), controlled for covariates.
RESULTS
Psychosocial risk was more prevalent in men than in women (21.4% vs 17.5%, p < 0.001). Seven out of 10 AEs were more likely in women than in men (e.g., infection 44.5% vs 39.2%, p < 0.001). The association of psychosocial risk with each AE was either stronger in women than in men (e.g., device malfunction HRadj 1.29, 95% confidence interval (CI) (1.06-1.56) vs HRadj 1.10, 95% CI (0.97-1.25); rehospitalization HRadj 1.15, 95% CI (1.02-1.29) vs HRadj 1.03, 95% CI (0.97-1.10) or similar between sexes.
CONCLUSIONS
Independent of clinical parameters, the presence of psychosocial risk is associated with increases in AEs. This suggests that early modification of psychosocial risk factors may have the potential to lower the risk for AEs in this patient population.