MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvs.2022.11.037

Медицинская библиотека · Journal of vascular surgery · 2022

Systematic review of reintervention with fenestrated or branched devices after failed previous endovascular aortic aneurysm repair.

Nana Petroula, Kölbel Tilo, Behrendt Christian-Alexander, Kouvelos George, Giannoukas Athanasios, Haulon Stephan, Spanos Konstantinos

СтатьяСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

A proximal seal extension, after previously failed standard endovascular abdominal aortic aneurysm repair (EVAR), has been described using various endovascular techniques. The aim of the present systematic review was to assess the technical success, 30-day mortality, and mortality and reintervention rates during the available follow-up for patients managed with endovascular methods after failed endovascular repair.

METHODS

The present systematic review followed the PRISMA (preferred reporting items for systematic reviews and meta-analyses) statement and was preregistered at PROSPERO (no. CRD42022350436). A search of the English literature, via Ovid, using the MEDLINE, EMBASE, and CENTRAL databases, until June 15, 2022, was performed. Observational studies (2000-2022) and case series with at least five patients who had undergone fenestrated/branched EVAR (F/BEVAR) after failed EVAR were considered eligible. Technical success and mortality at 30 days and the mortality and reintervention rates during available follow-up had to have been reported. The Newcastle-Ottawa scale was used to assess the risk of bias. The primary outcome was technical success and mortality at 30 days.

RESULTS

The initial search yielded 2558 reports. Ten studies were considered eligible, two of which were prospective. A total of 423 patients had undergone F/BEVAR after failed EVAR. The indication for reintervention was the presence of a type Ia endoleak in 44.9%. Technical success was reported in seven studies, and 319 of 336 interventions were considered successful (94.9%), according to each study's criteria. Of the 423 patients, 10 had died within 30 days (2.4%). Seven patients had presented with spinal cord ischemia (2.4%). Twenty-three acute kidney injury events were reported (6.8%). The mean follow-up was 18 months (range, 1-77 months). During follow-up, 47 deaths were reported (14.8%). Finally, 50 reinterventions of 303 procedures (16.5%) had been performed.

CONCLUSIONS

According to the available literature, F/BEVAR after failed EVAR can be performed with high technical success and low mortality during the perioperative period. The midterm mortality and reintervention rates were acceptable. However, further data are needed to provide firm conclusions regarding the safety and durability of F/BEVAR after failed EVAR.

Для цитирования: Nana Petroula, Kölbel Tilo, Behrendt Christian-Alexander, Kouvelos George, Giannoukas Athanasios, Haulon Stephan, Spanos Konstantinos. Systematic review of reintervention with fenestrated or branched devices after failed previous endovascular aortic aneurysm repair.. Journal of vascular surgery. 2022. DOI: 10.1016/j.jvs.2022.11.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…