mm-Wave Radar-Based Vital Signs Monitoring and Arrhythmia Detection Using Machine Learning.

Iyer Srikrishna, Zhao Leo, Mohan Manoj Prabhakar, Jimeno Joe, Siyal Mohammed Yakoob, Alphones Arokiaswami, Karim Muhammad Faeyz

СтатьяПеревод пока не подготовлен

Аннотация

A non-contact, non-invasive monitoring system to measure and estimate the heart and breathing rate of humans using a frequency-modulated continuous wave (FMCW) mm-wave radar at 77 GHz is presented. A novel diagnostic system is proposed which extracts heartbeat phase signals from the FMCW radar (reconstructed using Fourier series analysis) to test a three-layer artificial neural network model to predict the presence of arrhythmia in individuals. The effect of person orientation, distance of measurement and movement was analyzed with respect to a reference device based on statistical measures that include number of outliers, mean, mean squared error (MSE), mean absolute error (MAE), median absolute error (medAE), skewness, standard deviation (SD) and R-squared values. The individual oriented in front of the radar outperformed almost all other orientations for most distances with an expected d = 90 cm and d = 120 cm. Furthermore, it was found that the heart rate that was measured while walking and the breathing rate which was measured for a motionless individual generated results with the lowest SD and MSE. An artificial neural network (ANN) was trained using the MIT-BIH database with a training accuracy of 93.9 % and an R2 value = 0.876. The diagnostic tool was tested on 15 subjects and achieved a mean test accuracy of 75%.

Для цитирования: Iyer Srikrishna, Zhao Leo, Mohan Manoj Prabhakar, Jimeno Joe, Siyal Mohammed Yakoob, Alphones Arokiaswami, Karim Muhammad Faeyz. mm-Wave Radar-Based Vital Signs Monitoring and Arrhythmia Detection Using Machine Learning.. Sensors (Basel, Switzerland). 2022. DOI: 10.3390/s22093106.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.