MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2021.11.050

Медицинская библиотека · Journal of the American College of Cardiology · 2022

Myocardial Fibrosis Predicts Ventricular Arrhythmias and Sudden Death After Cardiac Electronic Device Implantation.

Leyva Francisco, Zegard Abbasin, Okafor Osita, Foley Paul, Umar Fraz, Taylor Robin J, Marshall Howard, Stegemann Berthold, Moody William, Steeds Richard P, Halliday Brian P, Hammersley Daniel J, Jones Richard E, Prasad Sanjay K, Qiu Tian

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Increasing evidence supports a link between myocardial fibrosis (MF) and ventricular arrhythmias.

OBJECTIVES

The purpose of this study was to determine whether presence of myocardial fibrosis on visual assessment (MFVA) and gray zone fibrosis (GZF) mass predicts sudden cardiac death (SCD) and ventricular fibrillation/sustained ventricular tachycardia after cardiac implantable electronic device (CIED) implantation.

METHODS

In this prospective study, total fibrosis and GZF mass, quantified using cardiovascular magnetic resonance, was assessed in relation to the primary endpoint of SCD and the secondary, arrhythmic endpoint of SCD or ventricular arrhythmias after CIED implantation.

RESULTS

Among 700 patients (age 68.0 ± 12.0 years), 27 (3.85%) experienced a SCD and 121 (17.3%) met the arrhythmic endpoint over median 6.93 years (IQR: 5.82-9.32 years). MFVA predicted SCD (HR: 26.3; 95% CI: 3.7-3,337; negative predictive value: 100%). In competing risk analyses, MFVA also predicted the arrhythmic endpoint (subdistribution HR: 19.9; 95% CI: 6.4-61.9; negative predictive value: 98.6%). Compared with no MFVA, a GZF mass measured with the 5SD method (GZF5SD) >17 g was associated with highest risk of SCD (HR: 44.6; 95% CI: 6.12-5,685) and the arrhythmic endpoint (subdistribution HR: 30.3; 95% CI: 9.6-95.8). Adding GZF5SD mass to MFVA led to reclassification of 39% for SCD and 50.2% for the arrhythmic endpoint. In contrast, LVEF did not predict either endpoint.

CONCLUSIONS

In CIED recipients, MFVA excluded patients at risk of SCD and virtually excluded ventricular arrhythmias. Quantified GZF5SD mass added predictive value in relation to SCD and the arrhythmic endpoint.

Для цитирования: Leyva Francisco, Zegard Abbasin, Okafor Osita, Foley Paul, Umar Fraz, Taylor Robin J, Marshall Howard, Stegemann Berthold, Moody William, Steeds Richard P, Halliday Brian P, Hammersley Daniel J, Jones Richard E, Prasad Sanjay K, Qiu Tian. Myocardial Fibrosis Predicts Ventricular Arrhythmias and Sudden Death After Cardiac Electronic Device Implantation.. Journal of the American College of Cardiology. 2022. DOI: 10.1016/j.jacc.2021.11.050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало