MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2022.02.016

Медицинская библиотека · International journal of cardiology · 2022

Improved prediction of electrical storm in patients with prior myocardial infarction and implantable cardioverter defibrillator.

Faga Valentina, Anguera Ignasi, Oloriz Teresa, Nombela-Franco Luis, Teruel Luis, Dallaglio Paolo, Perez Guerrero Ainhoa, Hernando Salazar Carlos, Escaned Javier, Asso Abadía Antonio, Gomez Hospital Joan Antoni, Rodriguez García Julián, Rodriguez García Marcos, Comin Colet Josep, Di Marco Andrea

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: To evaluate predictors of electrical storm (ES), including chronic total occlusion in an infarct-related coronary artery (infarct-related artery CTO, IRACTO), in a cohort of patients with prior myocardial infarction (MI) and implantable cardioverter-defibrillators (ICD).

METHODS

Multicenter observational cohort study including 643 consecutive patients with prior MI and a first ICD implanted between 2005 and 2018 at three tertiary hospitals. All the patients included in the study had undergone a diagnostic coronary angiography before ICD implantation. The variable prior ventricular arrhythmias (VA+) was positive in patients with secondary prevention ICDs and in those with at least one appropriate ICD therapy after primary prevention implantation.

RESULTS

During a median follow-up of 42 months 59 patients (9%) suffered ES. The presence of at least one IRACTO not revascularized (IRACTO-NR) was associated with a significantly higher cumulative incidence of ES (14.5% vs 4.8%, p < 0.001). IRACTO-NR maintained a significant association with ES after adjustment for potential confounders (HR 2.3, p = 0.005) and was an independent predictor of ES together with VA+ and LVEF. The best cut-off of LVEF to predict ES was ≤38%. A risk-prediction model based on IRACTO-NR, VA+ and LVEF≤38% identified three categories of ES risk (low, intermediate and high), with progressively increasing cumulative incidence of ES (2.2%, 9% and 20%).

CONCLUSION

In a cohort of patients with prior MI and ICD, IRACTO-NR is an independent predictor of ES. A new risk-prediction model allowed the identification of three categories of risk, with potentially important clinical implications.

Для цитирования: Faga Valentina, Anguera Ignasi, Oloriz Teresa, Nombela-Franco Luis, Teruel Luis, Dallaglio Paolo, Perez Guerrero Ainhoa, Hernando Salazar Carlos, Escaned Javier, Asso Abadía Antonio, Gomez Hospital Joan Antoni, Rodriguez García Julián, Rodriguez García Marcos, Comin Colet Josep, Di Marco Andrea. Improved prediction of electrical storm in patients with prior myocardial infarction and implantable cardioverter defibrillator.. International journal of cardiology. 2022. DOI: 10.1016/j.ijcard.2022.02.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.