BACKGROUND

Implantable cardioverter-defibrillators (ICDs) are recommended for patients with cardiac sarcoidosis (CS) with an indication for pacing, prior ventricular arrhythmias, cardiac arrest, or left ventricular ejection fraction <35%, but data on outcomes are limited.

METHODS

Using data from the National Cardiovascular Data Registry ICD Registry between April 1, 2010 and December 31, 2015, we evaluated a propensity matched cohort of CS patients implanted with ICDs versus non-ischemic cardiomyopathies (NICM). We compared mortality using Kaplan-Meier survival curves and Cox proportional hazards models.

RESULTS

We identified 1,638 patients with CS and 8,190 propensity matched patients with NICM. The rate of death at 1 and 2 years was similar in patients with CS and patients with NICM (5.2% vs 5.4%, P = 0.75 and 9.0% vs 9.3%, P = 0.72, respectively). After adjusting for other covariates, patients with CS had similar mortality at 2 years after ICD implantations compared with NICM patients (RR 1.03, 95% CI 0.87-1.23). Among patients with CS, multivariable logistic regression identified 6 factors significantly associated with increased 2-year mortality: presence of heart failure (HR 1.92, 95% CI 1.44-3.22), New York Heart Association (NYHA) Class III heart failure (HR 1.68, 95% CI 1.16-2.45), NYHA Class IV heart failure (HR 3.08, 95% CI 1.49-6.39), atrial fibrillation/flutter (HR 1.66, 95% CI 1.17-2.35), chronic lung disease (HR 1.64, 95% CI 1.17-2.29), creatinine >2.0 mg/dL (HR 4.07, 95% CI 2.63-6.30), and paced rhythm (HR 2.66, 95% CI 1.07-6.59).

CONCLUSION

Mortality following ICD implantation was similar in CS patients compared with propensity matched NICM patients. Presence of heart failure, NYHA class, atrial fibrillation/flutter, chronic lung disease, renal dysfunction, and paced rhythm at time of implantation were all predictors of increased 2-year mortality among CS patients with ICDs.

Для цитирования: Higgins Angela Y, Annapureddy Amarnath R, Wang Yongfei, Minges Karl E, Bellumkonda Lavanya, Lampert Rachel, Rosenfeld Lynda E, Jacoby Daniel L, Curtis Jeptha P, Miller Edward J, Freeman James V. Risk and predictors of mortality after implantable cardioverter-defibrillator implantation in patients with sarcoid cardiomyopathy.. American heart journal. 2021. DOI: 10.1016/j.ahj.2021.12.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.