MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm10081745

Медицинская библиотека · Journal of clinical medicine · 2021

Cardiac Implantable Electronic Devices in Hemodialysis and Chronic Kidney Disease Patients-An Experience-Based Narrative Review.

Nowak Krzysztof, Kusztal Mariusz

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Cardiovascular implantable electronic devices (CIEDs) are a standard therapy utilized for different cardiac conditions. They are implanted in a growing number of patients, including those with chronic kidney disease (CKD) and end-stage kidney disease (ESKD). Cardiovascular diseases, including heart failure and malignant arrhythmia, remain the leading cause of mortality among CKD patients, especially in ESKD. CIED implantation procedures are considered minor surgery, typically with transvenous leads inserted via upper central veins, followed by an impulse generator introduced subcutaneously. A decision regarding optimal hemodialysis (HD) modality and the choice of permanent vascular access (VA) could be particularly challenging in CIED recipients. The potential consequences of arteriovenous access on the CIED side are related to (1) venous hypertension from lead-related central vein stenosis and (2) the risk of systemic infection. Therefore, when creating permanent vascular access, the clinical scenario may be complicated by the CIED presence on one side and the lack of suitable vessels for arteriovenous fistula on the contralateral arm. These factors suggest the need for an individualized approach according to different clinical situations: (1) CIED in a CKD patient; (2) CIED in a patient on hemodialysis CIED; and (3) VA in a patient with CIED. This complex clinical conundrum creates the necessity for close cooperation between cardiologists and nephrologists.

Для цитирования: Nowak Krzysztof, Kusztal Mariusz. Cardiac Implantable Electronic Devices in Hemodialysis and Chronic Kidney Disease Patients-An Experience-Based Narrative Review.. Journal of clinical medicine. 2021. DOI: 10.3390/jcm10081745.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.