MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2021.01.017

Медицинская библиотека · JACC. Clinical electrophysiology · 2021

A Normal Electrocardiogram Does Not Exclude Infra-Hisian Conduction Disease in Patients With Myotonic Dystrophy Type 1.

Creta Antonio, Providência Rui, Gossios Thomas, Elliott Perry M, Turner Chris, Savvatis Konstantinos, Segal Oliver R

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study aimed to identify electrocardiographic (ECG) predictors of a prolonged His-ventricular (HV) interval in patients with type 1 myotonic dystrophy (DM1).

BACKGROUND

Patients with DM1 have an increased risk of sudden cardiac death. The presence of His-Purkinje system disease/prolonged HV interval (≥70 ms) is associated with a higher risk of potentially life-threatening bradyarrhythmic events.

METHODS

Electrophysiology studies (EPSs) were performed in all DM1 patients referred to 2 tertiary centers for routine cardiac assessment. In a subgroup of patients, the EPS was repeated at varying intervals.

RESULTS

A total of 154 patients (mean age: 43.7 ± 13.3; 58.1% male) underwent 202 diagnostic EPSs. HV ≥70 ms was found on 58 EPSs (28.7%); 9 of 59 patients (15.2%) with PR <200 ms and QRS interval <110 ms on baseline ECG had an HV ≥70 ms on EPS. Among those with PR ≥200 ms and/or QRS interval ≥100 ms, only 33.9% had an HV ≥70 ms on EPS. There were 38 patients who underwent repeated EPS, in which 28.8% demonstrated a prolongation of the HV interval overall compared with baseline. QRS duration demonstrated the most powerful discriminative capacity for HV ≥70 ms (area under the receiver operating characteristic curve: 0.76; 95% confidence interval [CI]: 0.68 to 0.84; p < 0.001). On multivariate analysis, QRS interval ≥112 ms had the highest predictive value for HV ≥70 ms (odds ratio: 7.94; 95% CI: 3.85 to 16.37.

CONCLUSIONS

ECG parameters have a poor predictive value for infra-Hisian conduction block in DM1 patients. QRS and PR intervals are normal in up to 15.2% of DM1 patients with prolonged HV, and 66.1% of those with PR ≥200 ms and/or QRS ≥100 ms do not have advanced His-Purkinje conduction system disease on EPS. Electrophysiology testing should be a mandatory part of screening for all patients to guide prophylactic pacemaker implantation.

Для цитирования: Creta Antonio, Providência Rui, Gossios Thomas, Elliott Perry M, Turner Chris, Savvatis Konstantinos, Segal Oliver R. A Normal Electrocardiogram Does Not Exclude Infra-Hisian Conduction Disease in Patients With Myotonic Dystrophy Type 1.. JACC. Clinical electrophysiology. 2021. DOI: 10.1016/j.jacep.2021.01.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.