MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15910199251358597

Медицинская библиотека · Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025

A single-center study of the RED 72 reperfusion catheter with SENDit technology in proximal large vessel occlusions.

Dhar Vidhya, Barrera Pablo Valdes, Akkipeddi Sajal Medha K, Gunturi Aditya, Dogra Neil, Schartz Derrek, Cotroneo Matthew J, Houk Clifton, Thompson Lewis, Ellens Nathaniel R, Matouk Charles, Nguyen Vincent N, Mattingly Thomas K, Bhalla Tarun, Bender Matthew T

СтатьяПеревод пока не подготовлен

Аннотация

BackgroundDelivery assist catheters are a new class of devices designed to better navigate tortuous segments and reach the clot interface in mechanical thrombectomy. The RED 72 aspiration catheter with SENDit technology is one such example. SENDit is a novel tapered obturator used instead of a microcatheter to bring up the RED 72. It was designed to speed materials setup and overcome "ledge" effect. This case series aims to assess the safety, efficacy, and associated materials costs of SENDit in a postmarket study.MethodsThis was a single-institution retrospective case series of endovascular thrombectomy for anterior circulation large vessel occlusions affecting the internal carotid artery, M1, or M2 treated with SENDit between August 2023 and May 2024. Demographic, clinical, and cost variables were collected.ResultsMedian time from groin puncture to first pass was 14.0 min, and median time from groin puncture to recanalization was 25.0 min. Modified first-pass effect (mTICI ≥2b) was achieved in 51.4% of cases. The final recanalization mTICI ≥2b rate was 91.9%. A stentriever was required for 10.8% of cases. The rate of functional independence (mRS 0-2) at 3 months follow-up was 43.8%. The average materials cost per case was $7517.40 ± $2795.25; 10.8% of patients experienced access site complications. There was no artery dissection, and the rate of symptomatic intracerebral hemorrhage was 5.4%.ConclusionIn this case series, SENDit achieved a high rate of first pass effect, rapid recanalization, and low stentriever use and materials cost. It is safe given the low rate of procedural complications and favorable clinical outcomes. Delivery assist catheters are a promising alternative to stentrievers.

Для цитирования: Dhar Vidhya, Barrera Pablo Valdes, Akkipeddi Sajal Medha K, Gunturi Aditya, Dogra Neil, Schartz Derrek, Cotroneo Matthew J, Houk Clifton, Thompson Lewis, Ellens Nathaniel R, Matouk Charles, Nguyen Vincent N, Mattingly Thomas K, Bhalla Tarun, Bender Matthew T. A single-center study of the RED 72 reperfusion catheter with SENDit technology in proximal large vessel occlusions.. Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences. 2025. DOI: 10.1177/15910199251358597.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.