Comparison of multiple red cell volume methods performed concurrently in premature infants following allogeneic transfusion.
Аннотация
BACKGROUND
Study of the pathophysiology and treatment of anemia of prematurity is facilitated by direct measurement of red cell volume (RCV) utilizing microliter quantities of blood samples. Our objective was to compare concurrent measurements of multiple direct RCV methods in infants.
METHODS
Eighteen preterm infants receiving clinically indicated transfusions had concurrent flow cytometric determinations of RCV and 24-h red blood cell (RBC) recovery based on donor-recipient differences of biotin-labeled RBCs (BioRBCs), Kidd antigen mismatched RBCs, and fetal hemoglobin-positive (HbF(+)) RBCs. High-performance liquid chromatography (HPLC) was also used for measuring HbF and adult hemoglobin protein concentrations for the determination of RCV.
RESULTS
Concurrent RCV measurements using BioRBCs (18 and 54 µg/ml), Kidd antigen, and HbF flow cytometry were not statistically different compared with RCVs measured using the reference BioRBC density (6 µg/ml). By contrast, the HbF-HPLC method overestimated RCV by 45% compared with the reference method. All the methods demonstrated 100% 24-h posttransfusion RBC recovery (PTR24).
CONCLUSION
Because BioRBC, Kidd antigen, and fetal hemoglobin (HbF) flow cytometry are safe and accurate methods requiring <10 µl of patient blood for determining RCV and PTR24 in preterm infants, they can be useful in clinical and research studies of anemia and other conditions.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.