MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivx026

Медицинская библиотека · Interactive cardiovascular and thoracic surgery · 2017

Right atrium positioning for exposure of right pulmonary veins during off-pump atrial fibrillation ablation.

Suwalski Grzegorz, Emery Robert, Mróz Jakub, Kaczejko Kamil, Gryszko Leszek, Cwetsch Andrzej, Skrobowski Andrzej

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Concomitant surgical ablation of atrial fibrillation (AF) is recommended for patients undergoing off-pump coronary revascularization in the presence of this arrhythmia. Achievement of optimal visualization of pulmonary veins while maintaining stable haemodynamic conditions is crucial for proper completion of the ablation procedure. This study evaluates the safety and feasibility of right atrial positioning using a suction-based cardiac positioner as opposed to compressive manoeuvres for exposure during off-pump surgical ablation for AF.

METHODS

Thirty-four consecutive patients underwent pulmonary vein isolation, ganglionated plexi ablation and left atrial appendage occlusion during off-pump coronary artery bypass grafting. Right atrial suction positioning was used to visualize right pulmonary veins. Safety and feasibility end points were analysed intraoperatively and in the early postoperative course.

RESULTS

In all patients, right atrial positioning created optimal conditions to complete transverse and oblique sinus blunt dissection, correct placement of a bipolar ablation probe, detection and ablation of ganglionated plexi and conduction block assessment. In all patients, this entire right-sided ablation procedure was completed with a single exposure manoeuvre. Feasibility end points were achieved in all study patients.

CONCLUSIONS

This report documents the safety and feasibility of right atrial exposure using a suction-based cardiac positioner to complete ablation for AF concomitant with off-pump coronary revascularization. This technique may be widely adopted to create stable haemodynamic conditions and optimal visualization of the right pulmonary veins.

Для цитирования: Suwalski Grzegorz, Emery Robert, Mróz Jakub, Kaczejko Kamil, Gryszko Leszek, Cwetsch Andrzej, Skrobowski Andrzej. Right atrium positioning for exposure of right pulmonary veins during off-pump atrial fibrillation ablation.. Interactive cardiovascular and thoracic surgery. 2017. DOI: 10.1093/icvts/ivx026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.