MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15266028261424099

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026

A Novel Method Improving Estimation of Distal Landing Zone and Remodeling in Endovascular Repair of Type B Aortic Dissection.

Zhao Yang, Qian Jiesheng, He Haipeng, Lin Ren, Lv Junbin, Peng Jiaxin, Zhang Yibo, Chen Huining, Yin Henghui

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Tapered stent graft has been used to reduce distal stent graft-induced new entry (SINE), but there is no solid evidence for distal size selection about grafting in the dissected distal landing zone. We aimed to estimate the distal stent size based on the estimated normal aorta before dissection onset and remodeling after thoracic endovascular aortic repair (TEVAR) in the study.

METHODS

Patients received TEVAR from July 2016 to June 2024 were regrouped into 3 groups based on differentials between estimated distal stent size and actual distal stent size (group A: differentials within 0-1 mm; group B: actual distal stent size smaller than estimated distal stent size, differentials >1 mm; group C: actual distal stent size larger than estimated distal stent size, differentials >1 mm). Remodeling condition was divided into full remodeling (complete false lumen reduction), complete false lumen thrombosis, and non-remodeling. Clinical and morphological data were collected and analyzed. Risk factors of full remodeling and survival data were determined and evaluated.

RESULTS

Ninety patients were included in this study. Full remodeling was significantly satisfied in group A (78.1%) than in group B (21.4%) and group C (46.7%, p<0.05). Distal SINE was significantly higher in group C (13.3%) than group A (0%) and group B (0%, p<0.05). The cumulative 5-year full remodeling rate was significantly higher in group A than in group B and group C (p<0.05). Multivariate Cox regression analysis revealed that differentials between estimated distal stent size and actual distal stent size were a significant predictive factor of full remodeling after TEVAR (p<0.05).

CONCLUSION

Distal stent size selected by estimated normal aorta size could promote full remodeling at the dissected aorta after TEVAR, with low risk of distal SINE.Clinical ImpactDistal stent size selected by estimated normal aorta size could promote aortic remodeling and false lumen complete reduction (full remodeling) at stented section after endovascular therapy in type B dissection patient.

Для цитирования: Zhao Yang, Qian Jiesheng, He Haipeng, Lin Ren, Lv Junbin, Peng Jiaxin, Zhang Yibo, Chen Huining, Yin Henghui. A Novel Method Improving Estimation of Distal Landing Zone and Remodeling in Endovascular Repair of Type B Aortic Dissection.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2026. DOI: 10.1177/15266028261424099.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.