The Use of a New Dedicated Electrocautery Lumen-Apposing Metal Stent for Gallbladder Drainage in Patients with Acute Cholecystitis.

Brandaleone Luca, Franchellucci Gianluca, Facciorusso Antonio, Samanta Jayanta, Moon Jong Ho, Vargas-Madrigal Jorge, Robles Medranda Carlos, Barbera Carmelo, Di Matteo Francesco, Bulajic Milutin, Auriemma Francesco, Paduano Danilo, Calabrese Federica, Gentile Carmine, Massidda Marco, Bianchi Marco, De Luca Luca, Polverini Davide, Masoni Benedetta, Poletti Valeria, Marcozzi Giacomo, Hassan Cesare, Repici Alessandro, Mangiavillano Benedetto

СтатьяПеревод пока не подготовлен

Аннотация

Aims: Lumen-apposing metal stents (LAMSs) in ultrasonography-guided gallbladder drainage (EUS-GBD) have become increasingly important for high-risk surgical patients. Our study aims to evaluate the technical and clinical success, safety, and feasibility of endoscopic ultrasonography-guided gallbladder drainage using a new dedicated LAMS.

Methods

This is a retrospective multicenter study that included all consecutive patients not suitable for surgery who were referred to a tertiary center for EUS-GBD using a new dedicated electrocautery LAMS for acute cholecystitis at eight different centers.

Results

Our study included 54 patients with a mean age of 76.48 years (standard deviation: 12.6 years). Out of the 54 endoscopic gallbladder drainages performed, 24 (44.4%) were cholecysto-gastrostomy, and 30 (55.4%) were cholecysto-duodenostomy. The technical success of LAMS placement was 100%, and clinical success was achieved in 23 out of 30 patients (76.67%). Adverse events were observed in two patients (5.6%). Patients were discharged after a median of 5 days post-stenting.

Conclusions

EUS-GBD represents a valuable option for high-surgical-risk patients with acute cholecystitis. This new dedicated LAMS has demonstrated a high rate of technical and clinical success, along with a high level of safety.

Для цитирования: Brandaleone Luca, Franchellucci Gianluca, Facciorusso Antonio, Samanta Jayanta, Moon Jong Ho, Vargas-Madrigal Jorge, Robles Medranda Carlos, Barbera Carmelo, Di Matteo Francesco, Bulajic Milutin, Auriemma Francesco, Paduano Danilo, Calabrese Federica, Gentile Carmine, Massidda Marco, Bianchi Marco, De Luca Luca, Polverini Davide, Masoni Benedetta, Poletti Valeria, Marcozzi Giacomo, Hassan Cesare, Repici Alessandro, Mangiavillano Benedetto. The Use of a New Dedicated Electrocautery Lumen-Apposing Metal Stent for Gallbladder Drainage in Patients with Acute Cholecystitis.. Diagnostics (Basel, Switzerland). 2023. DOI: 10.3390/diagnostics13213341.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.