Safety and adverse events of EUS-guided gallbladder drainage using lumen-apposing metal stents and percutaneous cholecystostomy tubes: a systematic review and meta-analysis.
Аннотация
BACKGROUND AND AIMS: EUS-guided gallbladder drainage using lumen-apposing metal stents (EUS-GBD-LAMSs) and percutaneous cholecystostomy for gallbladder drainage (PTGBD) are the alternative treatment modalities in high-risk surgical patients with acute cholecystitis (AC). The aim of this study was to compare the safety of these procedures for AC in surgically suboptimal candidates.
METHODS
Six studies compared the 2 groups' early, delayed, and overall adverse events; they also compared length of hospital stay, re-interventions, and re-admissions rate. A random effect model calculated odds ratios (ORs) with a 95% confidence interval (CI).
RESULTS
The 2 groups had similar early adverse events; however, EUS-GBD-LAMS was associated with a lower rate of delayed (OR, .21; 95% CI, .07-.61; P ≤ .01) and overall (OR, .43; 95% CI, .30-.61; P ≤ .01) adverse events. Patients with EUS-GBD-LAMSs had a shorter hospital stay than PTGBD.
CONCLUSIONS
EUS-GBD-LAMS is a safer option than PTGBD and is associated with a shorter hospital stay in nonsurgical candidates with AC.